Hitachi Presto
System, X-Ray, Tomography, Computed. 510(k) K040902, from Hitachi Medical Systems America, Inc. (Twinsburg, OH). Product code JAK, class 2.
As of Nov 19, 2026, K040902 is an FDA 510(k) held by Hitachi Medical Systems America, Inc., substantially equivalent on Apr 21, 2004 after 14 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 14 days
- Recalls: 4
- Cited as a predicate by: 4 devices
The Presto Computed Tomography system is an x-ray imaging device that produces cross-sectional images of the body at different angles. The system reconstructs, processes, displays, and stores the collected images. The device output can provide an aid to diagnosis when used by a qualified physician.
- ProntoK014240 · Hitachi Medical Systems America, Inc. · Mar 22, 2002
- Guideshot Option for CXR4 and Eclos CT SystemsK091103 · Hitachi Medical Systems America, Inc. · Jun 15, 2009
- Eclos Computed Tomography X-Ray SystemK071806 · Hitachi Medical Systems America, Inc. · Aug 28, 2007
- CXR16K053148 · Hitachi Medical Systems America, Inc. · Feb 17, 2006
- Sceptrep3 Pet/CtK042428 · Hitachi Medical Systems America, Inc. · Sep 17, 2004
| Apr 14, 2009 | Z-1651-2009Incorrect scale on image: A software error can occur if two (2) different Field-of-View (FOV) settings are registered in a protocol using Multi-Reconstruction. This could cause the image generated to be displayed with… | Terminated |
| Nov 5, 2008 | Z-0608-2009Software error: The device has a software error that can result in a condition where the displayed image orientation does not match the display orientation markers (right-left reversal). | Terminated |
| Feb 21, 2006 | Z-1078-06The device has a software anomaly which affects the system's ability to create Multiplanar Reconstructions (MPR). Some images from the resulting series do not display correctly, or display at all, when MPR was run on… | Terminated |
| Feb 21, 2006 | Z-1079-06The device has a software anomaly which causes blank images to be created during Multiplanar Reconstruction processing or results in an inherent filming error in which a reference scale is improperly sized. | Terminated |
- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated, third-party review
- Received
- Apr 7, 2004
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files