Exactech Resorbable Room Temperature Bone Paste
Filler, Bone Void, Calcium Compound. 510(k) K040755, from Exactech, Inc. (Gainesville, FL). Product code MQV, class 2.
As of Nov 18, 2026, K040755 is an FDA 510(k) held by Exactech, Inc., substantially equivalent on Jun 17, 2004 after 85 days, with no recalls tied to it in FDA's recall database.
- Review time: 85 days
- Recalls: 0
- Cited as a predicate by: 3 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFExactech Resorbable Room Temperature Bone Paste is intended for use as a bone graft extender (extremities, spine, pelvis) and as a bone void filler for bony voids or gaps of the extremities and pelvis that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Exactech Resorbable Bone PasteK020078 · Exactech, Inc. · Feb 27, 2004
Cited as a predicate
3 later 510(k) summaries name this device as a predicate- OptecureK050806 · Exactech, Inc. · Feb 8, 2006
- Viagraf Dbm PasteK043209 · Osteotech, Inc. · Dec 5, 2005
- Grafton Plus Dbm PasteK043048 · Osteotech, Inc. · Nov 23, 2005
Other MQV clearances
The newest 510(k)s for the same product code; their median review was 96 days; see every MQV device- Mg OSTEOREVIVE™;Mg OSTEOCRETE™K262230 · Bone Solutions, Inc. · Sep 11, 2026
- Device 300419 StripK260364 · Geistlich Pharma AG · Jun 2, 2026
- JAZBI™ Resorbable Bone Void FillerK252797 · Sdip Innovations Pty, Ltd. · May 26, 2026
- Vitoss® BiModal Bioactive Bone Graft Substitute Foam Strip; Vitoss® BiModal Bioactive Bone Graft Substitute; Vitoss…K261008 · Stryker Spine · Apr 24, 2026
- Adaptos®Fuse Bone GraftK253524 · Biomendex OY · Feb 17, 2026
- FIBERGRAFT™ BG Putty GPS Bone Graft Substitute FIBERGRAFT™ BG Putty Bone Graft Substitute FIBERGRAFT™ AERIDYAN™ Matrix…K253147 · Prosidyan, Inc. · Oct 22, 2025
- Mg OSTEOINJECT™; Mg OSTEOREVIVE™; Mg OSTEOCRETE™K251522 · Bone Solutions, Inc. · Oct 13, 2025
- Allomatrix (Allomatrix Injectable Putty; Allomatrix C; Allomatrix DR; Allomatrix Custom)K252085 · Wright Medical Technology, Inc. (Stryker Corporation) · Sep 30, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Mar 24, 2004
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3045
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files