Flexifil Series HC431 Full Face Mask, Model HC431A

Ventilator, Non-Continuous (Respirator). 510(k) K040506, from Fisher & Paykel Healthcare, Ltd. (East Tamaki, Auckland, NZ). Product code BZD, class 2.

As of Nov 17, 2026, K040506 is an FDA 510(k) held by Fisher & Paykel Healthcare, Ltd., substantially equivalent on May 5, 2004 after 68 days, with 6 recalls tied to it in FDA's recall database.

  • Substantially equivalent: May 5, 2004
  • Review time: 68 days
  • Recalls: 6
  • Cited as a predicate by: 5 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The Fisher & Paykel Healthcare Flexifit™ Series HC431 Full Face Mask is an accessory to a Noncontinuous ventilator (IPPB) as per 73 BZD, 21 CFR §868.5905. The Flexifit™ Series HC431 Full Face Mask is indicated for use by adults requiring CPAP or Bilevel ventilator treatment in home, hospital and laboratory environments for the treatment of Obstructive Sleep Apnea (OSA).

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

5 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K040506, newest first; each opens FDA's recall record
Nov 24, 2006Z-0973-2007Plastic tabs incorporated into the connector components of these CPAP masks may break off if they are not cleaned in accordance with the Instructions for Use. In the event of a tab breaking off, it may enter the CPAP…Terminated
Nov 24, 2006Z-0969-2007Plastic tabs incorporated into the connector components of these CPAP masks may break off if they are not cleaned in accordance with the Instructions for Use. In the event of a tab breaking off, it may enter the CPAP…Terminated
Nov 24, 2006Z-0972-2007Plastic tabs incorporated into the connector components of these CPAP masks may break off if they are not cleaned in accordance with the Instructions for Use. In the event of a tab breaking off, it may enter the CPAP…Terminated
Nov 24, 2006Z-0970-2007Plastic tabs incorporated into the connector components of these CPAP masks may break off if they are not cleaned in accordance with the Instructions for Use. In the event of a tab breaking off, it may enter the CPAP…Terminated
Nov 24, 2006Z-0974-2007Plastic tabs incorporated into the connector components of these CPAP masks may break off if they are not cleaned in accordance with the Instructions for Use. In the event of a tab breaking off, it may enter the CPAP…Terminated
Nov 24, 2006Z-0971-2007Plastic tabs incorporated into the connector components of these CPAP masks may break off if they are not cleaned in accordance with the Instructions for Use. In the event of a tab breaking off, it may enter the CPAP…Terminated

Other BZD Clearances

The newest 510(k)s for the same product code; their median review was 263 days; see every BZD device

Record

Type
Traditional
Received
Feb 27, 2004
Review panel
Anesthesiology
Regulation
21 CFR 868.5905

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files