Cem-Ostetic Putty Injection Kit, Model Pik-Xx, Pik-Xx-Yy
Filler, Bone Void, Calcium Compound. 510(k) K040405, from Berkeley Advanced Biomaterials, Inc. (San Leandro, CA). Product code MQV, class 2.
As of Nov 19, 2026, K040405 is an FDA 510(k) held by Berkeley Advanced Biomaterials, Inc., substantially equivalent on Mar 5, 2004 after 17 days, with no recalls tied to it in FDA's recall database.
- Review time: 17 days
- Recalls: 0
- Cited as a predicate by: 1 device
Cem-Ostetic™ is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site.
- Osteofix Bone Void FillerK070220 · Calcitec, Inc. · Apr 12, 2007
- PearlBone™ Putty 1600K260496 · Marine Biomedical · Nov 2, 2026
- Mg OSTEOREVIVE™;Mg OSTEOCRETE™K262230 · Bone Solutions, Inc. · Sep 11, 2026
- Device 300419 StripK260364 · Geistlich Pharma AG · Jun 2, 2026
- JAZBI™ Resorbable Bone Void FillerK252797 · Sdip Innovations Pty, Ltd. · May 26, 2026
- Vitoss® BiModal Bioactive Bone Graft Substitute Foam Strip; Vitoss® BiModal Bioactive Bone Graft Substitute; Vitoss…K261008 · Stryker Spine · Apr 24, 2026
- Adaptos®Fuse Bone GraftK253524 · Biomendex OY · Feb 17, 2026
- FIBERGRAFT™ BG Putty GPS Bone Graft Substitute FIBERGRAFT™ BG Putty Bone Graft Substitute FIBERGRAFT™ AERIDYAN™ Matrix…K253147 · Prosidyan, Inc. · Oct 22, 2025
- Mg OSTEOINJECT™; Mg OSTEOREVIVE™; Mg OSTEOCRETE™K251522 · Bone Solutions, Inc. · Oct 13, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Feb 17, 2004
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3045
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files