Iv Administration And Connect Sets
Set, Administration, Intravascular. 510(k) K033301, from Codan US Corp. (Santa Ana, CA). Product code FPA, class 2.
As of Nov 18, 2026, K033301 is an FDA 510(k) held by Codan US Corp., substantially equivalent on Mar 4, 2004 after 142 days, with 1 recall tied to it in FDA's recall database.
- Substantially equivalent: Mar 4, 2004
- Review time: 142 days
- Recalls: 1
- Cited as a predicate by: 1 device
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Nephros Olpur H2H Hemodiafiltration (Hdf) Module And Olpur Md 220 HemodiafilterK112314 · Nephros, Inc. · Apr 27, 2012
Recalls
Recalls FDA ties to K033301, newest first; each opens FDA's recall record| Started | Reason | Status |
|---|---|---|
| Sep 12, 2019 | Z-2433-2020Individual packages of connectors may have incomplete or bad seals which would compromise sterility. | Terminated |
Other FPA Clearances
The newest 510(k)s for the same product code; their median review was 266 days; see every FPA device- Gravity Blood Sets with 200µm FilterK260261 · B.Braun Medical, Inc. · Oct 22, 2026
- Ecomed Disposable Administration SetsK254123 · Ecomed Solutions, LLC · Sep 11, 2026
- iiSure Infusion SetK261530 · Deka Research and Development · Jun 3, 2026
- AMSafe Administration Set (BA-70075, BA-70071-D, BA-70070, BA-70071-P, BA-70072, BA-70072-F, BA-70071-DF,…K252543 · Amsino International, Inc. · May 4, 2026
- PuraCath Firefly Needleless Connector IT (9005)K251375 · Puracath Medical, Inc. · Feb 12, 2026
- nSet+ Stabilization Set [6426733]; nSet+ Stabilization Set with nSyte Needle Free Connector (NFC) [6426731]; nSyte…K251257 · Np Medical · Dec 4, 2025
- BD Alaris Pump Infusion SetK250325 · Carefusion (Bd) · Oct 30, 2025
- EZ™ IV Administration SetK251814 · Epic Medical Pte. , Ltd. · Aug 29, 2025
Record
- Type
- Traditional
- Received
- Oct 14, 2003
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5440
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files