Modification To: The Margron Hip Replacement System

Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate. 510(k) K032641, from Portland Orthopaedics Pty. , Ltd. (Matraville Nsw, AU). Product code MEH, class 2.

As of Nov 19, 2026, K032641 is an FDA 510(k) held by Portland Orthopaedics Pty. , Ltd., substantially equivalent on Jan 20, 2004 after 146 days, with 25 recalls tied to it in FDA's recall database.

  • Review time: 146 days
  • Recalls: 25+

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The MARGRON™ Hip Replacement System is intended for primary or revision restruction, without bone cement, of the femoral portion of a severely disabled and/or very painful hip joint, where radiographic evidence of sufficient sound bone is present. The patient should be skeletally mature.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K032641, newest first; the 25 newest; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Jan 11, 2008Z-1990-2008, Z-1996-2008, Z-1995-2008, Z-1949-2008, Z-1962-2008, Z-1931-2008, Z-1976-2008, Z-1938-2008, Z-1956-2008, Z-1999-2008, Z-1964-2008, Z-1983-2008, Z-1985-2008, Z-1957-2008, Z-1991-2008, Z-1959-2008, Z-1970-2008, Z-1950-2008, Z-1986-2008, Z-1954-2008, Z-1975-2008, Z-1969-2008, Z-1965-2008, Z-1993-2008, Z-1961-2008Australian data indicates the product is associated with a higher than average rate of hip replacement revision surgery.Terminated

Other MEH clearances

The newest 510(k)s for the same product code; their median review was 90 days; see every MEH device

Record

Type
Special
Received
Aug 27, 2003
Review panel
Orthopedic
Regulation
21 CFR 888.3353

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files