Arca
Skip to content
Tools
Tools

Mini V.A.C., V.A.C. Freedom, V.A.C. Ats

Negative Pressure Wound Therapy Powered Suction Pump. 510(k) K032310, from Kinetic Concepts, Inc. (San Antonio, TX). Product code OMP, class 2.

As of Nov 18, 2026, K032310 is an FDA 510(k) held by Kinetic Concepts, Inc., substantially equivalent on Oct 10, 2003 after 74 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 74 days
  • Recalls: 2
  • Cited as a predicate by: 14 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The V.A.C® family of devices with woundsite feedback control are negative pressure devices used to help promote wound healing, through means including drainage and removal of infectious material or other fluids, under the influence of continuous and/or intermittent negative pressures, particularly for patients with chronic, acute, traumatic, subacute and dehisced wounds, partial-thickness burns…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF
  • V.A.C. PlusK992448 · Kinetic Concepts, Inc. · Jan 18, 2000
  • AmbuvacK971548 · Kinetic Concepts, Inc. · May 22, 1997

Cited as a predicate

14 later 510(k) summaries name this device as a predicate; the 12 newest

Recalls

Recalls FDA ties to K032310, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Sep 16, 2005Z-0379-06Possible mislabeling of shipping cartons.Terminated
Sep 21, 2004Z-0038-05The seal on the dressing pouch may open during shipping and sterility of the dressing may be compromised.Terminated

Other OMP clearances

The newest 510(k)s for the same product code; their median review was 240 days; see every OMP device

Record

Type
Traditional
Received
Jul 28, 2003
Review panel
General, Plastic Surgery
Regulation
21 CFR 878.4780

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.