2.4 Smartnail, Models 532416, 532425, 532435, 532445
Fastener, Fixation, Biodegradable, Soft Tissue. 510(k) K031981, from Linvatec Biomaterials, Ltd. (Largo, FL). Product code MAI, class 2.
As of Nov 18, 2026, K031981 is an FDA 510(k) held by Linvatec Biomaterials, Ltd., substantially equivalent on Jul 25, 2003 after 29 days, with no recalls tied to it in FDA's recall database.
- Review time: 29 days
- Recalls: 0
Indications for use
As the 510(k) summary states them, read from FDA's summary PDF2.4 SmartNail is intended for use in the fixation of fragments of fractured non-load bearing bones, osteotomies and arthrodeses, for example in the fixation of apical fragments, osteochondral fragments and cancellous/non-load bearing fragments.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Smart Nail Models 521516, 521520,521525, 531516, 531520. 531525K993074 · Bionx Implants, Ltd. · Dec 10, 1999
- 1.5MM Bone Fixation KitK012000 · Bionx Implants, Ltd. · Jul 18, 2001
- Modification To: 1.5 Bone Fixation Kit, Models BXS6114, BXS6214K013546 · Bionx Implants, Inc. · Nov 21, 2001
Other MAI clearances
The newest 510(k)s for the same product code; their median review was 57 days; see every MAI device- SF Push-in AnchorK263244 · Surgical Fusion Technologies GmbH · Nov 5, 2026
- Arthrex Bioabsorbable PushLock Suture AnchorsK262357 · Arthrex, Inc. · Aug 7, 2026
- Arthrex Bioabsorbable PushLock Suture AnchorsK253931 · Arthrex, Inc. · May 28, 2026
- SF Push-in AnchorK260294 · Surgical Fusion Technologies GmbH · Mar 27, 2026
- OSSIOfiber® Suture AnchorK254055 · OSSIO , Ltd. · Feb 24, 2026
- Biosteon® ScrewK251680 · Biocomposites, Ltd. · Feb 17, 2026
- BioBrace® Extra-Articular Ligament Augmentation KitK252946 · Conmed Corporation · Oct 15, 2025
- OSSIOfiber® Interference ScrewK252022 · OSSIO , Ltd. · Aug 19, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 26, 2003
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files