Rapido Cut-Away Bleedback Control Valve (Bbcv), Model 7568
Oxygenator, Cardiopulmonary Bypass. 510(k) K031903, from Guidant Corporation (St Paul, MN). Product code DTZ, class 2.
As of Nov 22, 2026, K031903 is an FDA 510(k) held by Guidant Corporation, substantially equivalent on Mar 3, 2004 after 257 days, with 1 recall tied to it in FDA's recall database.
- Review time: 257 days
- Recalls: 1
The Guidant Bleedback Control Valve is intended for maintaining a seal around diagnostic/interventional devices with an outside diameter of less than 0.185" in the venous anatomy only, during interventional procedures.
- Copilot Bleedback Control Valve, Model 1003331K991102 · Guidant Corp. · Jun 9, 1999
| Started | Recall | Status |
|---|---|---|
| Jan 7, 2011 | Z-2793-2011Five lots of Guide Catheters and Accessory products were processed through Ethylene Oxide (ETO) sterilization with additional plastic material covering the pallet, which is not consistent with validated packaging… | Terminated |
- HORIZON 8AF (Integrated OXY MODULE 8AF and Horizon CVR) (US5305)K261438 · Eurosets S.R.L · Sep 14, 2026
- Lifemotion Disposable Membrane OxygenatorK253838 · Lifemotion Medical Technology Co., Ltd. · Mar 16, 2026
- Quantum Perfusion Blood Oxygenator ECC VT160-E3 (VT160-E3); Quantum Perfusion Blood Oxygenator ECC VT200-E3 (VT200-E3);…K240934 · Spectrum Medical S.R.L. · Mar 12, 2026
- Horizon AF Plus System (Integrated A.L. One AF Plus OXYGENATOR and Horizon CVR) (US5300); A.L. One AF Plus OXYGENATOR…K250821 · Eurosets S.R.L · Dec 12, 2025
- Trilly Pediatric Oxygenator with Integrated Arterial Filter (US5232)K242503 · Eurosets S.R.L · Nov 24, 2025
- Quantum Perfusion Blood Oxygenator VT75-E1, Quantum Perfusion Blood Oxygenator VT75-E2K231982 · Qura S.R.L · Sep 12, 2024
- Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator…K240666 · Medtronic Perfusion Systems · Jul 10, 2024
- Affinity NT Oxygenator and Uncoated Cardiotomy/ Venous Reservoir (541); Affinity NT Oxygenator with Balance Biosurface…K241352 · Medtronic, Inc. · Jun 12, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 20, 2003
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.4350
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files