Siemens Infinity Modular Monitors, Models SC 7000, SC 9000XL and SC 8000 With VF3 Modifications
Detector And Alarm, Arrhythmia. 510(k) K031433, from Siemens Medical Solutions USA, Inc. (Danvers, MA). Product code DSI, class 2.
As of Nov 20, 2026, K031433 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Aug 19, 2003 after 105 days, with no recalls tied to it in FDA's recall database.
- Review time: 105 days
- Recalls: 0
The INFINITY Modular monitors are capable of monitoring: • Heart rate - Respiration rate • Invasive pressure • Non-invasive pressure - Arrhythmia • Temperature • Cardiac output • Arterial oxygen saturation - Pulse rate - Apnea • ST Segment Analysis • 12-Lead ST Segment Analysis - tcpO2/tcpCO2 • EEG signals - FiO2 (Diffusion Sign-Off) Division of Anesthesiology, General Hospital, Infection…
- Siemens SC 8000 Bedside MonitorK983632 · Siemens Medical Solutions USA, Inc. · Nov 6, 1998
- Siemens SC 8000 Bedside Monitor With Advanced Communication OptionK990563 · Siemens Medical Solutions USA, Inc. · Mar 19, 1999
- Siemens Infinity Modular Monitors Model SC 8000; SC 7000; SC 9000XLK003243 · Siemens Medical Solutions USA, Inc. · Dec 21, 2000
- SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorK982730 · Siemens Medical Solutions USA, Inc. · Aug 24, 1998
- Siemens SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorK980882 · Siemens Medical Solutions USA, Inc. · Jun 5, 1998
- BodyGuardian Remote Monitoring System (BGRMS v3.0)K243349 · Boston Scientific Cardiac Diagnostic Technologies, Inc. · Jan 23, 2026
- MoMe ARC® Wireless Ambulatory ECG Monitoring and Detection System (32000)K250356 · Infobionic, Inc. · Jul 29, 2025
- Zio AT® device (A100A1001)K240177 · iRhythm Technologies, Inc. · Oct 30, 2024
- MoMe® ARC Wireless Ambulatory ECG Monitoring and Detection SystemK230265 · Infobionic, Inc. · Oct 6, 2023
- SmartCardia 7L PlatformK231276 · Smartcardia SA · Aug 30, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- May 6, 2003
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files