D-10 Hemoglobin A1C
Assay, Glycosylated Hemoglobin. 510(k) K031043, from Bio-Rad Laboratories, Inc. (Hercules, CA). Product code LCP, class 2.
As of Nov 20, 2026, K031043 is an FDA 510(k) held by Bio-Rad Laboratories, Inc., substantially equivalent on Aug 27, 2003 after 148 days, with 6 recalls tied to it in FDA's recall database.
- Review time: 148 days
- Recalls: 6
- Cited as a predicate by: 2 devices
The Bio-Rad D-10 Hemoglobin A₁c Program is intended for the percent determination of hemoglobin A₁c in human whole blood using ion-exchange high performance liquid chromatography (HPLC). The D-10 Hemoglobin A₁c Program is intended for use only with the Bio-Rad D-10 Hemoglobin Testing System. For In Vitro Diagnostic Use.
- Variant Ii Hemoglobin A1C ProgramK984268 · Bio-Rad · Dec 17, 1998
- Hemoglobin Capillary Collection System (Hccs), 1 Test, Hemoglobin Capillary Collection System (Hccs), 5 Tests, HemoglobiK090737 · Bio-Rad Laboratories, Inc. · Jun 3, 2009
- D-10 Hemoglobin A1C Program; D-10 Dual ProgramK060001 · Bio-Rad Laboratories, Inc. · Jan 20, 2006
| Feb 27, 2014 | Z-1299-2014On a rare occasion the D-10 software might generate an extra result by duplicating the result form the previous sample and the Sample ID/Injection number from the next sample. | Terminated |
| Nov 22, 2013 | Z-0965-2014D-10 A1c Dual Program Floppy was programmed incorrectly and cartridge injections counts are not being updated correctly when switching between the D-10 Dual Short Program and Extended Program on the D-10 Hemoglobin… | Terminated |
| Sep 12, 2011 | Z-0019-2012, Z-0017-2012, Z-0018-2012A previous recall related to reports of calibration failure and late retention times using Elution Buffer led to an examination of other buffers manufactured during the same time period and a decision was made to field… | Terminated |
| Sep 8, 2010 | Z-1969-2011The firm discovered that the Update Kit Floppy Diskette included in the reorder pack was mislabeled with an incorrect Lot Number for the Calibrator/Diluent Set as: S01819; The correct Lot Number for the… | Terminated |
- Q-Pad Test SystemK231465 · Qurasense · Dec 6, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 1, 2003
- Review panel
- Hematology
- Regulation
- 21 CFR 864.7470
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files