Hi-Torque Pilot 50 Guide Wire With Hydrocoat Hydrophilic Coating, Hi-Torque Pilot 150 Guide Wire With Hydrocoat Hydrophg
Wire, Guide, Catheter. 510(k) K030549, from Guidcorp (Temecula, CA). Product code DQX, class 2.
As of Nov 21, 2026, K030549 is an FDA 510(k) held by Guidcorp, substantially equivalent on May 14, 2003 after 82 days, with no recalls tied to it in FDA's recall database.
- Review time: 82 days
- Recalls: 0
- Cited as a predicate by: 3 devices
- Hi-Torque Whisper LS Guide Wire With Hydrocoat Hydrophilic Coating, Hi-Torque Whisper MS Guide Wire With Hydrocoat HydroK002206 · Guidant Corp. · Aug 24, 2000
- Hi-Toque Whisper LS and MS Guide Wire With Hydrocoat Hydrophilic CoatingK013092 · Guidant Corp. · Dec 13, 2001
- Modification To Hi-Torque Whisper LS and MS Guide Wires With Hydrocoat Hydrophilic CoatingK020340 · Guidant Corp. · Mar 1, 2002
- Progress Guide Wire Family, Pilot Guide Wire FamilyK123067 · Abbott Vascular, Inc. · Jan 29, 2013
- Hi-Torque Pilot 50 and 150 Guide Wire With Hydrocoat Hydrophilic Coating, Hi-Torque Whisper LS and MS Guide Wire WithK101116 · Abbott Vascular-Cardiac Therapies · Jun 23, 2010
- Hi-Torque Progress Guide Wire FamilyK091825 · Abbott Vascular, Inc. · Sep 25, 2009
- Small Diameter Core Wire (CMAN-000-00); Small Diameter Core Wire (CMAN-000-14)K260168 · Skycade Med Corporation · Oct 16, 2026
- Hyperdrive 35 GuidewireK253146 · Rapid-Medical , Ltd. · Sep 18, 2026
- CROSSLEAD Standard 035 and CROSSLEAD Stiff 035K261281 · Filmecc Co., Ltd. · Sep 3, 2026
- Accoat Guide WireK253667 · Sp Medical A/S · Jul 14, 2026
- Merit MAK Nitinol/Gold-Tungsten Guide WireK261640 · Merit Medical Ireland , Ltd. · Jul 13, 2026
- InQwire Amplatz Guide WireK254137 · Merit Medical Ireland, Ltd. · May 22, 2026
- FMD Peripheral Guide Wire F-14 Flex 6; FMD Peripheral Guide Wire F-14 Tapered 40; FMD Peripheral Guide Wire F-18 Flex…K260544 · FMD Co., Ltd. · Mar 20, 2026
- Enroute 0.014'' Transcarotid GuidewireK253746 · Lake Region Medical · Mar 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Feb 21, 2003
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1330
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files