Monodek Synthetic Absorbable Surgical Suture
Suture, Surgical, Absorbable, Polydioxanone. 510(k) K030212, from Genzyme Biosurgery (Fall River, MA). Product code NEW, class 2.
As of Nov 18, 2026, K030212 is an FDA 510(k) held by Genzyme Biosurgery, substantially equivalent on Mar 27, 2003 after 65 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 65 days
- Recalls: 3
- Cited as a predicate by: 1 device
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFMonodek™ Synthetic Absorbable Surgical Sutures are indicated for use in all types of soft tissue approximation, including use in pediatric cardiovascular tissue where growth is expected to occur and opthalmic surgery. Monodek suture is not indicated in adult cardiovascular tissue, microsurgery and neural tissue.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Mono-Dox, Synthetic Absorbable Polydioxanone Surgical Suture,SterileK013274 · Cp Medical · Nov 16, 2001
Cited as a predicate
1 later 510(k) summary names this device as a predicate- Digitex Suture Delivery System, Digitexpolypropylene Suture Cartridge Size 0, With Needle and Without Needle, DigitexK120284 · Coloplast A/S · May 23, 2012
Recalls
Recalls FDA ties to K030212, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Mar 11, 2014 | Z-1534-2014The product did not meet minimum and/or average minimum Teleflex resorption strength requirements. | Terminated |
| Mar 11, 2014 | Z-1509-2014Product does not meet minimum knot tensile strength requirements. | Terminated |
| Jun 6, 2007 | Z-1016-2007The products may not meet their final specifications for suture diameter and/or strength which could lead to premature breakage. | Terminated |
Other NEW clearances
The newest 510(k)s for the same product code; their median review was 273 days; see every NEW device- MINT MONO SuturesK254238 · Hans Biomed Corporation · Sep 18, 2026
- Monofix PdoK253879 · Samyang Holdings Corporation · Aug 25, 2026
- Monodek™ (POLYDIOXANONE) Dyed Violet Monofilament Synthetic Absorbable Surgical SutureK261988 · Teleflex Medical, LLC · Jul 9, 2026
- Barbed PDO SutureK252171 · Sutura Medical Technology, Inc. · Jun 12, 2026
- STRATAFIX™ Symmetric PDS™ Plus Knotless Tissue Control DevicesK252047 · ETHICON, Inc. · May 18, 2026
- PDS™ Plus Antibacterial (Polydioxanone) Sterile Synthetic Absorbable Surgical SutureK243897 · ETHICON, Inc. · Nov 12, 2025
- Miracu™ Polydioxanone (PDO) Suture and Needle (MONO)K251414 · Feeltech Co., Ltd. · Oct 20, 2025
- V-soft Line™ Barbed Surgical Suture (Various)K250107 · Feeltech Co., Ltd. · Oct 15, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 21, 2003
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4840
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files