Hand Innovations, Inc. Distal Radius Fracture Repair System
Plate, Fixation, Bone. 510(k) K030198, from Hand Innovations, Inc. (Weston, FL). Product code HRS, class 2.
As of Nov 18, 2026, K030198 is an FDA 510(k) held by Hand Innovations, Inc., substantially equivalent on Apr 1, 2003 after 70 days, with no recalls tied to it in FDA's recall database.
- Review time: 70 days
- Recalls: 0
- Cited as a predicate by: 4 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Distal Radius Fracture Repair System is intended for the fixation of fractures and osteotomies involving the distal radius.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Distal Radius Fracture Repair SystemK023007 · Hand Innovations, Inc. · Dec 5, 2002
Cited as a predicate
4 later 510(k) summaries name this device as a predicate- TDM Plate and Screw SystemK171808 · Tdm Co., Ltd. · Mar 15, 2018
- Distal Radius Locking Plating SystemK061917 · Newclip Technics · Aug 28, 2006
- Aptus Titanium Osteosynthesis SystemK051567 · Medartis, Inc. · Aug 23, 2005
- Distal Radius Fracture Repair SystemK032705 · Hand Innovations, Inc. · Oct 1, 2003
Other HRS clearances
The newest 510(k)s for the same product code; their median review was 73 days; see every HRS device- HERO Sternal Closure SystemK262939 · Hero Orthopedics, LLC · Nov 2, 2026
- Arthrex Plates, Screws and Pins, and WashersK263602 · Arthrex, Inc. · Oct 29, 2026
- Trochlear Salvage Plating SystemK261135 · Skeletal Dynamics, Inc. · Oct 26, 2026
- ANTHEM™ Fracture SystemK262779 · Globus Medical, Inc. · Oct 23, 2026
- Tempo Plating SystemK263407 · Pace Surgical · Oct 23, 2026
- Park's Pectus SystemK263269 · Tdm Co., Ltd. · Oct 15, 2026
- TDM Large Bone Plate and Screw SystemK261611 · Tdm Co., Ltd. · Oct 2, 2026
- Alians ForearmK262649 · Newclip Technics · Sep 28, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 21, 2003
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files