Freedom Constrained Liners
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer. 510(k) K030047, from Biomet, Inc. (Warsaw, IN). Product code KWZ, class 2.
As of Nov 18, 2026, K030047 is an FDA 510(k) held by Biomet, Inc., substantially equivalent on Jan 23, 2003 after 17 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jan 23, 2003
- Review time: 17 days
- Recalls: 0
- Cited as a predicate by: 4 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Freedom™ Constrained Liners are intended to replace a hip joint. The devices are intended for general use in skeletally mature individuals undergoing primary and/or secondary revision surgery at high risk of hip dislocation due to a history of prior dislocation, joint or bone loss, soft laxity, neuromuscular disease, or intra-operative instability and for whom all other options to constrained…
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Ringloc Constrained Liners IiK021728 · Biomet, Inc. · Oct 25, 2002
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- G7 Freedom and Offset Liners, Freedom Head, Size 32K142882 · Biomet, Inc. · Feb 10, 2015
- G7 Acetabular SystemK121874 · Biomet Manufacturing Corp · Nov 23, 2012
- Trident Constrained Acetabular InsertK061654 · Howmedica Osteonics Corp. · Jul 7, 2006
- Taperloc 12/14 Taper Femoral ComponentsK043537 · Biomet, Inc. · Jan 14, 2005
Other KWZ Clearances
The newest 510(k)s for the same product code; see every KWZ device- Mpact Constrained LinerK241461 · Medacta International S.A. · Jul 31, 2025
- PINNACLETM Constrained Acetabular LinersK240639 · Depuy Ireland UC · Apr 4, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jan 6, 2003
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3310
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files