Somatom Emotion 6 Ct Systems
System, X-Ray, Tomography, Computed. 510(k) K023687, from Siemens Medical Systems, Inc. (Iselin, NJ). Product code JAK, class 2.
As of Nov 17, 2026, K023687 is an FDA 510(k) held by Siemens Medical Systems, Inc., substantially equivalent on Nov 22, 2002 after 21 days, with 6 recalls tied to it in FDA's recall database.
- Substantially equivalent: Nov 22, 2002
- Review time: 21 days
- Recalls: 6
- Cited as a predicate by: 5 devices
Cited as a Predicate
5 later 510(k) summaries name this device as a predicate- Somatom Emotion 16K050297 · Siemens Medical Solution, Inc. USA · Mar 1, 2005
- Somatom Care Contrast CtK043087 · Siemens Medical Solutions USA, Inc. · Dec 15, 2004
- Somatom Respiratory GatingK043086 · Siemens Medical Solutions USA, Inc. · Dec 23, 2004
- Somatom Radiation Treatment Planning (Rtp) PackageK042229 · Siemens Medical Solution, Inc. USA · Sep 1, 2004
- Somatom Extended Field Of View Software OptionK032536 · Siemens Medical Solutions USA, Inc. · Nov 10, 2003
Recalls
Recalls FDA ties to K023687, newest first; each opens FDA's recall record| Feb 1, 2018 | Z-2472-2018A potential risk of unnecessary radiation exposure due to a software issue | Terminated |
| Feb 1, 2018 | Z-2473-2018A potential risk of unnecessary radiation exposure due to a software issue | Terminated |
| Feb 15, 2016 | Z-1300-2016Siemens is initiating this recall due to a potential malfunction and hence potential hazard to patients and personnel when using the SOMATOM Emotion or SOMATOM Sensation systems in conjunction with the use of the cardio… | Terminated |
| Mar 21, 2014 | Z-1721-2014The rubber damper may degrade and break, causing loosening of the motor mounting plates, which could lead to a series of events that could place the operator and patient at risk of injury. | Terminated |
| Aug 5, 2008 | Z-2452-2008Potential electrical shock hazard. The LCB power Switch (S1) could break causing the protective plastic cap to come off exposing the energized electrical contacts within the switch. The LCB S1 does have an inline fuse… | Terminated |
| Sep 28, 2004 | Z-0157-05Calcium Scoring feature on this devices is not closing properly after patient's exams. | Terminated |
Other JAK Clearances
The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Nov 1, 2002
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files