Modification To Radial Head Implant
Prosthesis, Elbow, Hemi-, Radial, Polymer. 510(k) K023604, from Avanta Orthopaedics, Inc. (San Diego, CA). Product code KWI, class 2.
As of Nov 19, 2026, K023604 is an FDA 510(k) held by Avanta Orthopaedics, Inc., substantially equivalent on Nov 27, 2002 after 30 days, with 18 recalls tied to it in FDA's recall database.
- Review time: 30 days
- Recalls: 18
- Cited as a predicate by: 2 devices
Avanta Orthopaedics Radial Head implant is intended for replacement of the proximal end of the radius: - Replacement of the radial head for degenerative, or post-traumatic disabilities presenting pain, crepitation and decreased motion at the radiohumeral and or proximal radio-ulnar joint with: • joint destruction or subluxation visible on x-ray • resistance to conservative treatment • Primary…
- Radial Head ImplantK982288 · Avanta Orthopaedics, Inc. · Sep 8, 1998
- Radial Head ImplantK002644 · Avanta Orthopaedics, Inc. · Nov 20, 2000
- Salto Talaris Total Ankle Prosthesis, RhsK130533 · Tornier S.A.S. · May 17, 2013
- RhsK060438 · Tornier · Apr 18, 2006
| Started | Recall | Status |
|---|---|---|
| Oct 24, 2017 | Z-2720-2018, Z-2717-2018, Z-2716-2018, Z-2691-2018, Z-2687-2018, Z-2718-2018, Z-2689-2018, Z-2713-2018, Z-2721-2018, Z-2692-2018, Z-2711-2018, Z-2712-2018, Z-2714-2018, Z-2715-2018, Z-2686-2018, Z-2690-2018, Z-2688-2018, Z-2719-2018Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. | Terminated |
- Arthrex Radial Head Replacement SystemK260624 · Arthrex, Inc. · Jul 30, 2026
- BioPoly Radial Head ImplantK233592 · BioPoly, LLC · Mar 13, 2024
- ALIGN Radial Head SystemK231188 · Skeletal Dynamics, Inc. · Sep 28, 2023
- DePuy Synthes Radial Head Replacement SystemK213563 · DePuy Synthes · Mar 18, 2022
- Avenger Radial Head SystemK212872 · In2bones USA, LLC · Dec 17, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Oct 28, 2002
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3170
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files