Alaris Medical Infusion System Administration Sets

Set, Administration, Intravascular. 510(k) K022209, from Alaris Medical Systems, Inc. (San Diego, CA). Product code FPA, class 2.

As of Nov 21, 2026, K022209 is an FDA 510(k) held by Alaris Medical Systems, Inc., substantially equivalent on Aug 6, 2002 after 29 days, with 8 recalls tied to it in FDA's recall database.

  • Review time: 29 days
  • Recalls: 8
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The following ALARIS Medical Infusion Systems are intended for use in today's growing professional healthcare environment including healthcare facilities, home care, and medical transport that utilize infusion systems for the delivery of fluids, medications, blood and blood products: - IVAC® Signature Edition® Infusion Pumps and Administration Sets.

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K022209, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 19, 2026Z-3080-2026Due to discrepancies in specific attributes in the performance data for infusion sets, which may lead to inappropriate pump performance.Open
Sep 11, 2025Z-0035-2026Infusion pump module used with compatible pump infusion sets may perform outside the established performance ranges for flow rate and bolus accuracy, downstream and upstream occlusion time to alarm, and post-occlusion…Open
Jul 8, 2025Z-2180-2025Infusion pump module used with compatible pump infusion sets may perform outside the established performance ranges for flow rate and bolus accuracy, downstream and upstream occlusion time to alarm, and post-occlusion…Open
Apr 18, 2024Z-1944-2024Due to infusion set tubing drip chamber becoming detached from the tubing potentially causing delays in treatment, or unintentionally exposing users to harsh infusates.Open
Oct 11, 2023Z-0349-2024, Z-0351-2024, Z-0350-2024Affected infusion sets labeled as free of DEHP actually do contain di(2-ethylhexyl) phthalate (DEHP).Open
Aug 10, 2006Z-1484-06This recall was initiated because of a potential for over infusion with all models of the Alaris SE Pumps (formerly the Signature Edition Infusion Pumps) caused by key bounce.Terminated

Other FPA clearances

The newest 510(k)s for the same product code; their median review was 266 days; see every FPA device

Record

Type
Special
Received
Jul 8, 2002
Review panel
General Hospital
Regulation
21 CFR 880.5440

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files