Over The Wire Embolectomy Catheter, Model 2302

Catheter, Embolectomy. 510(k) K022145, from LeMaitre Vascular, Inc. (Burlington, MA). Product code DXE, class 2.

As of Nov 19, 2026, K022145 is an FDA 510(k) held by LeMaitre Vascular, Inc., substantially equivalent on Jan 14, 2003 after 196 days, with 11 recalls tied to it in FDA's recall database.

  • Review time: 196 days
  • Recalls: 11
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The hemitre Over The Wire Embolectomy Catheter is indicated for use in the removal of emboli and thrombi during embolectomy and/or thrombectomy. It can also be used for catheter placement over a guidewire, vessel occlusion, fluid infusion and/or aspiration.

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K022145, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 28, 2026Z-0117-2027Devices failed in process testing related to the amount of pull force it can sustain prior to the balloon components failing.Open
Apr 11, 2025Z-1750-2025During internal product testing, it was observed that some packages to have incomplete seals (sterile barrier).Open
Mar 23, 2020Z-1567-2020There has been an increased trend in reports of catheters failing to deflate during use, which may ultimately lead to tip separation.Open
Oct 21, 2015Z-0384-2016, Z-0381-2016, Z-0379-2016, Z-0380-2016, Z-0382-2016, Z-0378-2016, Z-0385-2016, Z-0383-2016Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.Terminated

Other DXE clearances

The newest 510(k)s for the same product code; their median review was 173 days; see every DXE device

Record

Type
Traditional
Received
Jul 2, 2002
Review panel
Cardiovascular
Regulation
21 CFR 870.5150

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.