Infinion 0.6T Mr Imaging System
System, Nuclear Magnetic Resonance Imaging. 510(k) K013858, from Philips Medical Systems (Cleveland), Inc. (Cleveland, OH). Product code LNH, class 2.
As of Nov 18, 2026, K013858 is an FDA 510(k) held by Philips Medical Systems (Cleveland), Inc., substantially equivalent on Jan 22, 2002 after 62 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 62 days
- Recalls: 2
- Cited as a predicate by: 1 device
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Infinion 0.6T MR Imaging System does not change the existing indications as defined below. The Infinion 0.6T MR Imaging System is indicated for use as a NMR device that produces images that: (1) correspond to the distribution of protons exhibiting NMR, (2) depend upon the NMR parameters (proton density, flow velocity, spin-lattice relaxation time (T1), and spin-spin relaxation time (T2)) and…
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Outlook System Enhancement PackageK974844 · Philips Medical Systems (Cleveland), Inc. · Mar 10, 1998
Cited as a predicate
1 later 510(k) summary names this device as a predicate- Panorama EnhancementsK024042 · Philips Medical Systems, Inc. · Feb 4, 2003
Recalls
Recalls FDA ties to K013858, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Aug 7, 2013 | Z-0033-2014There is a potential for water to collect in the vent pipe elbow in the magnet venting system. Water may freeze, blocking the venting system. | Terminated |
| Sep 19, 2008 | Z-2434-2010Water may collect and freeze in the vent pipe. This can rupture the magnet vessel during a cryogen transfer, and release helium into the MRI suite. | Terminated |
Other LNH clearances
The newest 510(k)s for the same product code; their median review was 143 days; see every LNH device- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 21, 2001
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files