Revolution Formula 2

Material, Tooth Shade, Resin. 510(k) K013647, from Sybron Dental Specialties, Inc. (Orange, CA). Product code EBF, class 2.

As of Nov 19, 2026, K013647 is an FDA 510(k) held by Sybron Dental Specialties, Inc., substantially equivalent on Jan 16, 2002 after 72 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 72 days
  • Recalls: 1
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Revolution Formula 2 is a flowable, light cure hybrid resin restorative designed to be used as a filling material for Class III, Class IV, and Class V restorations. Additional functions include: repair of enamel defects, repair of porcelain restorations, minor occlusal build-ups in non-stress bearing areas, pit and fissure sealant, cement for ceramic/composite veneers, incisal abrasions, and core…

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K013647, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Oct 15, 2010Z-0716-2011Patterson Dental is conducting a recall because they have been advised by the manufacturer of Revolution Formula 2 (Kerr Corporation) that some syringes and tips marked with the brand name are not manufactured and…Terminated

Other EBF clearances

The newest 510(k)s for the same product code; their median review was 61 days; see every EBF device

Record

Type
Traditional
Received
Nov 5, 2001
Review panel
Dental
Regulation
21 CFR 872.3690

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files