BD Saf-T Prn Luer Activated Valve, Model 385100

Set, Administration, Intravascular. 510(k) K013621, from Becton Dickinson Infusion Therapy Systems, Inc. (Sandy, UT). Product code FPA, class 2.

As of Nov 20, 2026, K013621 is an FDA 510(k) held by Becton Dickinson Infusion Therapy Systems, Inc., substantially equivalent on Apr 16, 2002 after 162 days, with 11 recalls tied to it in FDA's recall database.

  • Review time: 162 days
  • Recalls: 11
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

21 CFR Part 880--GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices Sec. 880.5440: An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K013621, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Feb 19, 2015Z-1317-2015Becton Dickinson received an elevated number of complaints for blood or infusate/medication leakage due to tearing of the silicone septum.Terminated
Nov 6, 2009Z-1075-2010, Z-1073-2010, Z-1074-2010Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism.Terminated
Oct 19, 2009Z-0756-2010, Z-0754-2010, Z-0753-2010, Z-0751-2010, Z-0752-2010, Z-0755-2010, Z-0750-2010Manufacturing defect may allow air entry into a central venous catheter, possibly resulting in an air embolism.Terminated

Other FPA clearances

The newest 510(k)s for the same product code; their median review was 266 days; see every FPA device

Record

Type
Traditional
Received
Nov 5, 2001
Review panel
General Hospital
Regulation
21 CFR 880.5440

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files