Modification To: Datascope 8FR. Polyimide Alt B Iab, 25CC, 34CC, 40CC, Datascope Insertion Kit for 8 FR, Polyimide Alt B
System, Balloon, Intra-Aortic And Control. 510(k) K013326, from Datascope Corp. (Fairfield, NJ). Product code DSP, class 2.
As of Nov 26, 2026, K013326 is an FDA 510(k) held by Datascope Corp., substantially equivalent on Nov 2, 2001 after 28 days, with no recalls tied to it in FDA's recall database.
- Review time: 28 days
- Recalls: 0
- Cited as a predicate by: 4 devices
1. Refractory ventricular failure. 2. Cardiogenic shock. 3. Unstable refractory angina. 4. Impending infarction. 5. Mechanical complications due to acute myocardial infarction, i.e., ventricular septal defect, mitral regurgitation or papillary muscle rupture. 6. Ischemia related intractable ventricular arrhythmias. 7.
- Datascope Profile 8FR. Alt B Iab, 34CC, Datascope Profile 8FR. Alt B Iab, 40CC, Model 0684-000319, 0684-00-0320K003598 · Datascope Corp. · Dec 21, 2000
- Datascope's 8FR. Polymide 25CC,34CC and 40CC Iab and Accessories, Models 0684-00-0327, 06844-00-0328, 0684-00-0329K994157 · Datascope Corp. · Mar 13, 2000
- Guide Wire for The Use With Datascope Percor Stat-Dl IabsK943896 · Datascope Corp. · Dec 22, 1995
- Datascope's 8FR. 50CC Intra-Aortic Balloon Catheter and Accessories, Models 0684,00-0498-01, 02K091449 · Datascope Corp., Cardiac Assist Division · Jun 18, 2009
- Datascope 7.5FR. Iab Catheter and AccessoriesK041281 · Datascope Corp. · Jun 7, 2004
- Datascope Ca 40 8FR. Iabs, Model 0684-00-04XXK031569 · Datascope Corp. · Jun 10, 2003
- Datascope's 8FR. Alt B Iab; Datascope's Profile 8FR. Alt B Iab; Datascope's True Sheathless DL 9.5 FR. Iab; Datascope'sK020257 · Datascope Corp. · Apr 24, 2002
- AC3™ Range™ Intra-Aortic Balloon PumpK250542 · Arrow International, LLC · Mar 26, 2025
- AC3™ Series IABPK232343 · Arrow International, LLC · Aug 30, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Oct 5, 2001
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.3535
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files