Biocuff,C, Models 236018, 236028, 236036
Fastener, Fixation, Biodegradable, Soft Tissue. 510(k) K013057, from Bionx Implants, Inc. (Tampere, FI). Product code MAI, class 2.
As of Nov 17, 2026, K013057 is an FDA 510(k) held by Bionx Implants, Inc., substantially equivalent on Oct 12, 2001 after 30 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 12, 2001
- Review time: 30 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFProperly used, in the presence of adequate immobilization, absorbable BioCuff CTM screw/washer maintains proximity between soft tissue and bone to facilitate the soft tissue reattachment. The BioCuff CTM loses its strength over 20 to 50 weeks while the lesion of the tendon is healing.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Biocuff, Models 225718, 225728, 225736, 235718, 235728, 235736K001378 · Bionx Implants, Inc. · Jul 28, 2000
- Bionx Distal Radius ScrewK974876 · Bionx Implants, Inc. · Mar 20, 1998
- Cannulated Smartscrew Models 224540C, 224570CK992947 · Bionx Implants, Ltd. · Sep 21, 1999
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Impact Suture Anchor. Model 433510K030388 · Bionx Implants, Ltd. · Apr 24, 2003
- Duet Suture AnchorK020056 · Bionx Implants, Ltd. · Jun 26, 2002
Other MAI Clearances
The newest 510(k)s for the same product code; their median review was 57 days; see every MAI device- Arthrex Bioabsorbable PushLock Suture AnchorsK262357 · Arthrex, Inc. · Aug 7, 2026
- Arthrex Bioabsorbable PushLock Suture AnchorsK253931 · Arthrex, Inc. · May 28, 2026
- SF Push-in AnchorK260294 · Surgical Fusion Technologies GmbH · Mar 27, 2026
- OSSIOfiber® Suture AnchorK254055 · OSSIO , Ltd. · Feb 24, 2026
- Biosteon® ScrewK251680 · Biocomposites, Ltd. · Feb 17, 2026
- BioBrace® Extra-Articular Ligament Augmentation KitK252946 · Conmed Corporation · Oct 15, 2025
- OSSIOfiber® Interference ScrewK252022 · OSSIO , Ltd. · Aug 19, 2025
- OSSIOfiber® Suture AnchorK251309 · OSSIO , Ltd. · May 27, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Sep 12, 2001
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files