Medtronic PS Medical Strata Valve, Models 42855, 42865, 92865, 92855
Shunt, Central Nervous System And Components. 510(k) K012052, from Medtronic PS Medical (Goleta, CA). Product code JXG, class 2.
As of Nov 19, 2026, K012052 is an FDA 510(k) held by Medtronic PS Medical, substantially equivalent on Feb 11, 2002 after 224 days, with no recalls tied to it in FDA's recall database.
- Review time: 224 days
- Recalls: 0
- Cited as a predicate by: 5 devices
- Hakim Programmable Valve SystemK974739 · Johnson & Johnson Professionals, Inc. · Jul 1, 1998
- Hakim Micro Programmable Valve SystemK980778 · Johnson & Johnson Professionals, Inc. · Jul 17, 1998
- Sophy SU8 Pressure Adjustable ValveK992465 · Sophysa SA · Sep 21, 2000
- PS Medical Delta Csf-Flow Control ValveK902783 · Pudenz-Schulte Medical Research Corp. · Aug 8, 1990
- PS Medical Bioglide Csf-Flow Control Shunt KitK951258 · Pudenz-Schulte Medical Research Corp. · Sep 18, 1995
- Csf-Flow Control Valve, Cylindrical & Shunt KitK900676 · Pudenz-Schulte Medical Research Corp. · Apr 3, 1990
- Csf-Ventricular Catheter, Standard DesK792007 · Pudenz-Schulte Medical Research Corp. · Jan 16, 1980
- Csf-Cardiac/Peritoneal CatheterK792005 · Pudenz-Schulte Medical Research Corp. · Jan 16, 1980
- Medtronic PS Medical Strata Type ValueK060681 · Medtronic Neurosurgery · Sep 15, 2006
- Medtronic M2 Magnet Adjustment ToolK052386 · Medtronic Neurosurgery · Dec 16, 2005
- PS Medical Neurosurgical ImplantsK042198 · Medtronic Neurosurgery · Sep 24, 2004
- Medtronic StratavariusK041992 · Medtronic Neurosurgery · Jan 28, 2005
- Medtronic PS Medical Strata Nsc Valve and Shunt Assemblies With and Without BioglideK033850 · Medtronic Neurosurgery · Jan 13, 2004
- Ventricular Catheters, Thomale CatheterK260044 · Aesculap, Inc. · Oct 2, 2026
- Codman® Distal Peritoneal Catheter, Barium Open End (82-1682); Codman® HOLTER® Peritoneal Catheter (SALMON Design)…K261004 · Integra Lifesciences Production Corporation · Jun 23, 2026
- IntellidropK251598 · Brainspace, Inc. · Dec 10, 2025
- Sophy Mini Monopressure Valve (SM1)K250636 · Sophysa · Nov 28, 2025
- Codman Libertís Shunt Catheter with Bactiseal and Endexo TechnologyK243531 · Integra Lifesciences Production Corporation · Aug 8, 2025
- Codman Libertís™ 1.5 mm EVD Catheter with Bactiseal® and Endexo® Technology with Luer Connection (821761); Codman…K243552 · Integra Lifesciences Production Corporation · Aug 6, 2025
- External CSF Drainage Ventricular Catheters, External CSF Drainage Lumbar CathetersK242974 · Sophysa · Jun 20, 2025
- EvacK243205 · Phasor Health, LLC · Jun 3, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 2, 2001
- Review panel
- Neurology
- Regulation
- 21 CFR 882.5550
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files