Arca
Skip to content
Tools
Tools

Mini Multileaf Collimator, Model Kmi

Block, Beam-Shaping, Radiation Therapy. 510(k) K011816, from Mrc Systems GmbH (Heidelberg, DE). Product code IXI, class 2.

As of Nov 20, 2026, K011816 is an FDA 510(k) held by Mrc Systems GmbH, substantially equivalent on Sep 7, 2001 after 88 days, with no recalls tied to it in FDA's recall database.

  • Review time: 88 days
  • Recalls: 0
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Mini Multileaf Collimator is a conformal radiation therapy and-radiosurgery device that delivers a shaped X-ray beam from a radiation therapy source. The Mini Multileaf Collimator is attached to a linear accelerator and consists of a series of pairs of tungsten leaves that collimate radiation delivery to a target based on a treatment plan generated by planning software.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate
  • ModuleafK030609 · Mrc Systems GmbH · Mar 17, 2003

Other IXI clearances

The newest 510(k)s for the same product code; their median review was 92 days; see every IXI device

Record

Type
Traditional
Received
Jun 11, 2001
Review panel
Radiology
Regulation
21 CFR 892.5710

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.