Mac Two-Lumen Central Venous Kit With Arrowg Ard Blue Antimicrobial Surface and Integral Hemostasis Valve/Side Port
Introducer, Catheter. 510(k) K011761, from Arrow Intl., Inc. (Reading, PA). Product code DYB, class 2.
As of Nov 19, 2026, K011761 is an FDA 510(k) held by Arrow Intl., Inc., substantially equivalent on Oct 31, 2001 after 147 days, with 10 recalls tied to it in FDA's recall database.
- Review time: 147 days
- Recalls: 10
- Cited as a predicate by: 1 device
- 14 FR Two-Lumen Hemodialysis Catherization Kit With Blue Flextip Arrowg+Ard Blue Catheter for High Volume Infusions, ProK993933 · Arrow Intl., Inc. · Sep 14, 2000
- Two-Lumen Central Venous Access Kit With Hemostasis Valve/Side PortK002507 · Arrow Intl., Inc. · Mar 21, 2001
- Arrow Percutaneous Sheath Introducer Kit AK-07903K940079 · Arrow Intl., Inc. · Nov 30, 1994
- Ac 3 Lumen Central Venous Access Kit With Arrowg+Ard Antimicrobial SurfaceK032962 · Arrow Intl., Inc. · Oct 29, 2003
| Apr 21, 2026 | Z-2385-2026Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if… | Open |
| Aug 6, 2019 | Z-2555-2019Products may contain the incorrect banner card within the kit | Terminated |
| Apr 11, 2018 | Z-1983-2018Product sterility may be compromised due to unsealed packaging. | Terminated |
| Dec 22, 2017 | Z-1324-2018Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed. | Terminated |
| Nov 27, 2017 | Z-1002-2018, Z-1000-2018Some of the products listed in the recall may be missing a sticker that contains the lot number, expiration date, and Unique Device Identification (UDI) information. | Terminated |
| May 9, 2017 | Z-2333-2017Arrow International is recalling the affected product because the packaging may not be completely sealed, which may compromise sterility. | Terminated |
| Aug 27, 2015 | Z-2825-2015Manufacturer of 0.9% Sodium Chloride Flush Syringes recalled due to compromised sterility of the outer barrel, Arrow purchased recalled items that were packaged with certain products. | Terminated |
| Aug 6, 2014 | Z-0066-2015The component supplier recalled their 0.9% Sodium Chloride Injection USP BD Posiflush SF Saline Flush Syringe 10mL because some unit packages may exhibit open seals which impact package integrity and potentially product… | Terminated |
| Nov 24, 2009 | Z-0783-2010Q-Syte Component contained in kits was recalled by manufacturer due to the potential for embolism if used with a central venous catheter. | Terminated |
- Giranel Guiding Sheath SetK262674 · Kossel Medtech (Suzhou) Co., Ltd. · Oct 15, 2026
- NAMIC Dilator and SheathK253526 · Medline Industries, LP · Jul 29, 2026
- Micropuncture Kit / Micropuncture Access Kit / Micropuncture Introducer Set/ Microintroducer Kit / Microintroducer Kit…K261529 · Hartman Medical Group, LLC · Jul 6, 2026
- SimplGuideK261242 · Pendracare · Jun 25, 2026
- Health Line Tearaway IntroducerK261950 · Health Line International Corporation · Jun 22, 2026
- FieldFlex Steerable SheathK261492 · CenterPoint Systems, LLC · Jun 5, 2026
- Echo Large Bore Introducer SheathK260606 · Echo Medical, LLC · Apr 29, 2026
- Introducer Sheath SetK254248 · Cardiocycle Medical(Suzhou) Co., Ltd. · Apr 23, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 6, 2001
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1340
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files