Expedio 500D R&F X-Ray System

System, X-Ray, Fluoroscopic, Image-Intensified. 510(k) K011624, from GE Medical Systems (Waukesha, WI). Product code JAA, class 2.

As of Nov 19, 2026, K011624 is an FDA 510(k) held by GE Medical Systems, substantially equivalent on Jun 8, 2001 after 14 days, with 11 recalls tied to it in FDA's recall database.

  • Review time: 14 days
  • Recalls: 11
  • Cited as a predicate by: 1 device

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K011624, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Mar 29, 2019Z-1754-2019There has been a reported incident of a Distar CRT monitor that has fallen off the monitor wall mount related to product aging.Terminated
Feb 6, 2017Z-2179-2017Reported incidents of a patient step detaching from the table. A fall from a patient step detaching while in use could result in an injury to a patient or operator.Terminated
Nov 8, 2013Z-0804-2014Missing screws in the overhead Video Monitor Suspension. GE discovered that the 4 outer screws that hold the overhead Video Monitor Suspension to the carriage were missing since installation of the system. GE is not…Terminated
Aug 30, 2013Z-0012-2014GE Healthcare has recently become aware of a potential safety issue involving the spotfilm device power assist handle. There is a potential for the internal bolts on the power assist handle to be loose or to loosen…Terminated
May 2, 2013Z-1989-2013GE Healthcare has recently become aware of a potential safety issue involving the overhead Video Monitor Suspension involving Precision 500D Systems. There is a potential for the locking nut to loosen out of the Video…Terminated
Jan 2, 2008Z-1610-2008GE Healthcare was notified that 2 recently installed Precision 500D systems were not in compliance with portions of the Performance Standard for Diagnostic X-ray Equipment. X-ray production was possible from the…Terminated
Oct 4, 2007Z-0369-2008It was reported that when the GE Precision 500D foot pedal is repeatedly activated, a defect in the fluoro-timer will cause the dose measurement to report a higher value than was actually received by the patient.…Terminated
Aug 13, 2007Z-1477-2008Necessary certification labels are missing from the x-ray contol.Terminated
Aug 1, 2007Z-0274-2008Inaccurate cassette size display reading/ Inaccurate mAs reading: 1. When the device is in PBL mode and a larger film cassette is inserted into the table Bucky (replacing a smaller cassette) after a protocol is selected…Terminated
May 15, 2006Z-1304-06Systems are non-compliant with Federal Performance Standard Title 21, Code of Federal Regulation (CFR), 1020.32(a)(1) in that the systems allow the production of x-rays when the primary protective barrier is not in…Terminated
Dec 30, 2004Z-0220-05Units have a defect in accordance with 21 CFR 1003.2 because an incorrect exposure can occur.Terminated

Other JAA clearances

The newest 510(k)s for the same product code; their median review was 110 days; see every JAA device

Record

Type
Traditional, third-party review
Received
May 25, 2001
Review panel
Radiology
Regulation
21 CFR 892.1650

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files