Lifepak 12 Defibrillator/Monitor System
Automated External Defibrillators (Non-Wearable). 510(k) K010918, from Medtronic Physio-Control Corp. (Redmond, WA). Product code MKJ, class 3.
As of Nov 23, 2026, K010918 is an FDA 510(k) held by Medtronic Physio-Control Corp., substantially equivalent - subject to tracking reg. on Aug 23, 2001 after 149 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 149 days
- Recalls: 4
- Cited as a predicate by: 6 devices
- Lifepak 12K102972 · Physio-Control, Inc. · Dec 22, 2010
- Lifepak 12 Defibrillator/MonitorK063510 · Medtronic Emergency Response Systems, Inc. · Jan 26, 2007
- Highpak-12K062331 · Ad Elektronik GmbH · Jul 10, 2007
- Lifepak 12 Defibrillator/MonitorK041459 · Medtronic Emergency Response Systems, Inc. · Jul 1, 2004
- Lifepak 12K040775 · Medtronic Physio-Control Corp. · Apr 23, 2004
- Lifepak 12, 20, 500, CR PlusK033275 · Medtronic Physio-Control Corp. · Nov 6, 2003
| Oct 1, 2010 | Z-1548-2011L1FEPAK 12 Operating Instructions that describe the process for disconnecting the device from AC (wall) power are not always being followed. When the instructions are not followed and the Power ON button is pushed… | Terminated |
| Mar 22, 2006 | Z-0710-06Therapy connectors may have connector sockets that do not meet design specs - short drill depth. Interruption of the connections may cause unexpected, intermittent or complete loss of pacing and defibrillation functions. | Terminated |
| Jul 12, 2005 | Z-0004-06Some hard shell carry case for LIFEPAK 500 and LIFEPAK CR Plus automated external defibrillators may have blocked pressure vent which may make it difficult to open the case after a sudden decrease in altitude (such as… | Terminated |
| Jan 27, 2003 | Z-0542-03Impact and damage to the high voltage connectors results in poor or no electrical contact from the cable to the LIFEPAK 12 unit. | Terminated |
- Type
- Traditional
- Received
- Mar 27, 2001
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.5310
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files