Jax Granules Bone Void Filler
Filler, Bone Void, Calcium Compound. 510(k) K010557, from Smith & Nephew, Inc. (Memphis, TN). Product code MQV, class 2.
As of Nov 17, 2026, K010557 is an FDA 510(k) held by Smith & Nephew, Inc., substantially equivalent on May 25, 2001 after 88 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: May 25, 2001
- Review time: 88 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Ossipro Bone Substitute MaterialK062630 · Etex Corp. · Jun 28, 2007
- Osteo-G Bone Void Filler SystemK031319 · Aspine USA, Inc. · Jul 17, 2003
Other MQV Clearances
The newest 510(k)s for the same product code; their median review was 96 days; see every MQV device- Mg OSTEOREVIVE;Mg OSTEOCRETEK262230 · Bone Solutions, Inc. · Sep 11, 2026
- Device 300419 StripK260364 · Geistlich Pharma AG · Jun 2, 2026
- JAZBI Resorbable Bone Void FillerK252797 · Sdip Innovations Pty, Ltd. · May 26, 2026
- Vitoss® BiModal Bioactive Bone Graft Substitute Foam Strip; Vitoss® BiModal Bioactive…K261008 · Stryker Spine · Apr 24, 2026
- Adaptos®Fuse Bone GraftK253524 · Biomendex OY · Feb 17, 2026
- FIBERGRAFT BG Putty GPS Bone Graft Substitute FIBERGRAFT BG Putty Bone Graft Substitute…K253147 · Prosidyan, Inc. · Oct 22, 2025
- Mg OSTEOINJECT; Mg OSTEOREVIVE; Mg OSTEOCRETEK251522 · Bone Solutions, Inc. · Oct 13, 2025
- Allomatrix (Allomatrix Injectable Putty; Allomatrix C; Allomatrix DR; Allomatrix Custom)K252085 · Wright Medical Technology, Inc. (Stryker Corporation) · Sep 30, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 26, 2001
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3045
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files