Hitachi Altaire

System, Nuclear Magnetic Resonance Imaging. 510(k) K002420, from Hitachi Medical Systems America, Inc. (Twinsburg, OH). Product code LNH, class 2.

As of Nov 19, 2026, K002420 is an FDA 510(k) held by Hitachi Medical Systems America, Inc., substantially equivalent on Oct 17, 2000 after 70 days, with 8 recalls tied to it in FDA's recall database.

  • Review time: 70 days
  • Recalls: 8
  • Cited as a predicate by: 2 devices

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K002420, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Feb 11, 2008Z-1542-2008The firm's Altaire MR Scanner's Emergency Rundown Switch Unit (ERDU), that is used to shut down the device in an emergency, was found to be defective. An ERDU failure could delay or prevent patient access leading to…Terminated
Jul 30, 2007Z-1263-2007Overheating; A portion (balun assembly) of the cable that connects the shoulder coil to the actual MRI unit may malfunction and result in overheating of the balun assembly. The overheating of the balun assembly could…Terminated
Apr 28, 2006Z-1104-06Software anomaly-A software defect can cause the slice line indicator to become mis-positioned during Multi-Planar Reconstructions (MPR) with the potential for patient mis-diagnosis.Terminated
Feb 21, 2006Z-0910-06The device has a software anomaly which causes the operating system to 'lock up' and data to become corrupted during service procedures.Terminated
Jan 27, 2006Z-1103-06Circuit Failure-There is the potential risk of the Phase Loss Detector Safety Device (PHSEN PCB) malfunctioning in the event of a power loss. The circuit may fail to turn off the system main breaker when 2 of the 3…Terminated
Jun 30, 2005Z-0888-05Image reconstruction software problem that could potentially cause multiple patient images to be stored in one patient folder.Terminated
Apr 11, 2005Z-0797-05The electrical cables that supply gradient power to the magnet can become loose over time and create a potential fire hazard.Terminated
Nov 18, 2004Z-0846-05The absorber unit in the helium compressor which is located in equipment rooms, and is not accessed by patients or system operators, may fail under pressure, causing an explosion that damages the compressor.Terminated

Other LNH clearances

The newest 510(k)s for the same product code; their median review was 143 days; see every LNH device

Record

Type
Abbreviated
Received
Aug 8, 2000
Review panel
Radiology
Regulation
21 CFR 892.1000

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files