Gyroscan Intera (R7.5)
System, Nuclear Magnetic Resonance Imaging. 510(k) K001796, from Philips Medical Systems North America, Inc. (Shelton, CT). Product code LNH, class 2.
As of Nov 18, 2026, K001796 is an FDA 510(k) held by Philips Medical Systems North America, Inc., substantially equivalent on Sep 6, 2000 after 84 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 84 days
- Recalls: 4
- Cited as a predicate by: 4 devices
Cited as a predicate
4 later 510(k) summaries name this device as a predicate- Infinion Software FeaturesK024066 · Philips Medical Systems (Cleveland), Inc. · Feb 4, 2003
- Panorama EnhancementsK024042 · Philips Medical Systems, Inc. · Feb 4, 2003
- Tansmit/Receive Quadrature Body Coil 3.0TK013894 · Philips Medical Systems North America, Inc. · Jan 18, 2002
- Intera I/TK013344 · Philips Medical Systems North America Co. · Dec 11, 2001
Recalls
Recalls FDA ties to K001796, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Jul 6, 2015 | Z-1024-2016Wrong positioning of the coil cables can create unintended resonances via the patient or elevated coil cable temperature due to coupling to the QBC. The combined use of the Sense coil, high SAR level scanning and… | Terminated |
| May 1, 2009 | Z-0469-2011Combined use of the Synergy Flex-M / Shoulder Coil 1.5T increases the chance of RF interaction and heating up of the coil. This may result in possible burns of the patient. | Terminated |
| Apr 30, 2007 | Z-0982-2007Potential for gaseous helium to improperly vent, resulting in rupture of the magnet vessel and venting of helium into the MRI site. | Terminated |
| Aug 20, 2004 | Z-1488-04Potential for patient burn | Terminated |
Other LNH clearances
The newest 510(k)s for the same product code; their median review was 143 days; see every LNH device- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 14, 2000
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files