FDA establishment 3014307835, Phoenix, Arizona, United States. Part of Central Admixture Pharmacy Services's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 4
Official action indicated: 2
Last inspection ended: Sep 5, 2025
Warning letters: 0
Inspections by Fiscal Year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.160(a). Following/documenting laboratory controls Established standards, sampling plans and test procedures are not followed.
21 CFR 211.192. Written record of investigation incomplete Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
21 CFR 211.84(d)(2). Component written specification Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.84(d)(2). Establish reliability of supplier's C of A Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not fully followed.
Official Action Indicated (OAI)
Jul 31, 2023
Drugs · Drug Quality Assurance
17 cited references
21 CFR 211.130. Procedures are written, and followed Procedures designed to assure that correct labels are used for drug products are not followed.
21 CFR 211.166(a). Results not used for expiration dates, storage cond. Results of stability testing are not used in determining expiration dates.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
21 CFR 211.56(a). Sanitation--buildings not clean, free of infestation Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.
21 CFR 211.160(b)(4). Calibration - at intervals, written program, remedial action The calibration of instruments, apparatus and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
21 CFR 211.192. Quality control unit review of records Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
21 CFR 211.100(a). Absence of Written Procedures Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 310.305(c). Failure to submit ADE report Adverse drug experience information has not been reported to FDA.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.68(b). input/output verification Input to and output from the computer, related systems of formulas and records or data are not checked for accuracy.
21 CFR 211.160(b)(3). Drug products - samples representative, identified properly Samples taken of drug products for determination of conformance to written specifications are not properly identified.
21 CFR 211.42(c)(10)(vi). Equipment to control conditions Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
21 CFR 211.100(b). SOPs not followed / documented Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Official Action Indicated (OAI)
Feb 25, 2022
Drugs · Drug Quality Assurance
6 cited references
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
21 CFR 211.194(a)(5). Calculations performed are in the records Laboratory records do not include a record of all calculations performed in connection with the test.
21 CFR 211.42(c)(10)(vi). Equipment to control conditions Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
21 CFR 211.113(b). Validation lacking for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm.FDA Data Dashboard and warning letters