FDA establishment 3009968674, Sejong, Korea (the Republic of). Part of Nowcos's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, and the shipments FDA refused at the border.
Inspections: 3
Official action indicated: 3
Last inspection ended: Jun 19, 2026
Warning letters: 1
Import refusals since 2024: 26
Inspections by Fiscal Year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
21 CFR 211.84(a). Components withheld from use pending release Each lot of components and drug product containers is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
21 CFR 211.166(a). Written program not followed The written stability testing program is not followed.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Official Action Indicated (OAI)
Sep 6, 2019
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Aug 4, 2017
Drugs · Drug Quality Assurance
10 cited references
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.165(b). Microbiological testing Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.180(c). Records not made readily available to FDA Records associated with drug product and within the retention period for such records, were not made readily available for authorized inspection.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.42(c)(1). Incoming material area Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the receipt, identification, storage, and withholding from use of components and drug product containers pending sampling, testing, or examination by the quality control unit before release for manufacturing or packaging.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
21 CFR 211.194(d). Laboratory equipment calibration records Laboratory records do not include complete records of the periodic calibration of laboratory instruments.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Official Action Indicated (OAI)
Warning Letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm.FDA Data Dashboard and warning letters