Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.
FDA establishment 3007255059, Eumseong, Korea (the Republic of). Part of LCC Ltd.'s FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, and the shipments FDA refused at the border.
Inspections: 2
Official action indicated: 1
Last inspection ended: Mar 22, 2024
Warning letters: 2
Import refusals since 2024: 4
Inspections by Fiscal Year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.84(d)(2). Testing Each Component for Conformity with Specs Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.180(c). Records not made readily available to FDA Records associated with drug product components, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection.
21 CFR 211.198(b)(2). Complaint Investigation/Follow-Up Findings Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use and cleaning and maintenance.
21 CFR 211.22(c). Approve or reject procedures or specs The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
21 CFR 211.25(b). Supervisor Training/Education/Experience Individuals responsible for supervising the manufacture, processing, packing and holding of a drug product lack the education, training and experience to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.137(a). Expiration date lacking Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
Official Action Indicated (OAI)
Dec 15, 2017
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Warning Letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm.FDA Data Dashboard, warning letters and enforcement reports