Arca
Skip to content

QZH: Opioid Use Disorder Genetic Risk Variant Detection System And Collection Kit

FDA product code QZH. Class III. What the classification flags say about Part 820 under the QMSR.

As of Oct 26, 2026, FDA product code QZH (Opioid Use Disorder Genetic Risk Variant Detection System And Collection Kit) is Class III, reviewed through PMA, with 0 linked 510(k), De Novo or BK numbers, 1 PMA and 0 recall product records.

Classification

Product code
QZH
Device name
Opioid Use Disorder Genetic Risk Variant Detection System And Collection Kit
Device class
Class III
Regulation
FDA lists no classification regulation for this code
Review panel
Clinical Toxicology
Premarket route
PMA
CGMP-exempt flag
No
Life-sustaining flag
No
Implant flag
No
Third-party review
Not a candidate
Summary malfunction reporting
Ineligible

FDA definition. A qualitative in vitro molecular test that detects select variants in genomic DNA isolated from human specimens. Results of the test provide users with a genetic risk assessment of developing Opioid Use Disorder (OUD) and are intended to aid users with informed decision-making regarding the use of oral opioids for acute pain relief. The test may not include all variants associated with a risk of developing OUD and is not intended to describe a person’s overall risk of developing OUD. Results from the system are intended to be used in combination with clinical information and should not be the sole determinant in diagnosing, counseling, or making prescribing decisions

Data from openFDA as of 26 October 2026. Read the record on openFDA · FDA product code classification database

Part 820 requirements the flags point to

Part 820 rules for QZH

CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
Rule names this classRule names Class III.21 CFR 820.10(c) requires manufacturers of class II and class III devices to comply with clause 7.3 and its subclauses.21 CFR 820.10
Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
Not flaggedFDA does not flag this code as life-supporting or life-sustaining.820.10(d) is not indicated by this flag.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
Complaint and record content21 CFR 820.35
Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions

These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.

Clearances and recalls on record

510(k), De Novo and BK numbers linked
0
PMA numbers linked
1
Recall product records
0
Adverse event reports
Search MAUDE for QZH

Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.

Search all 7,097 product codes, or read the guide to the Part 820 rules behind these flags.

Check your quality documents against Part 820

Arca puts your SOPs and design files in a library and compares them against the Part 820 requirements for your device in a grid, one row per document and one column per requirement, with each cell cited to its source.

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.