Arca
Skip to content

OAW: Cancer Monitoring Test System, Soluble Mesothelin-Related Peptides, Epithelioid/Biphasic Mesothelioma

FDA product code OAW. HDE. What the classification flags say about Part 820 under the QMSR.

As of Nov 2, 2026, FDA product code OAW (Cancer Monitoring Test System, Soluble Mesothelin-Related Peptides, Epithelioid/Biphasic Mesothelioma) is HDE, reviewed through HDE (Humanitarian Device Exemption), with 0 linked 510(k), De Novo or BK numbers, 0 PMAs and 1 recall product record.

Classification

Product code
OAW
Device name
Cancer Monitoring Test System, Soluble Mesothelin-Related Peptides, Epithelioid/Biphasic Mesothelioma
Device class
HDE
Regulation
FDA lists no classification regulation for this code
Review panel
Immunology
Premarket route
HDE (Humanitarian Device Exemption)
CGMP-exempt flag
No
Life-sustaining flag
No
Implant flag
No
Third-party review
Not a candidate
Summary malfunction reporting
Eligible

FDA definition. A quantitative measurement of soluble mesothelin related peptides (smrp) in human serum. Measurement of smrp may aid in the monitoring of mesothelioma patients diagnosed with epithelioid or biphasic mesothelioma. Values must be interpreted in conjunction with all other available clinical laboratory data.

Data from openFDA as of 2 November 2026. Read the record on openFDA · FDA product code classification database

Part 820 requirements the flags point to

Part 820 rules for OAW

CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
Database cannot sayFDA lists the class as HDE.820.10(c) names class II, class III and listed class I devices. The database does not give one of those classes for an HDE code. Read the rule against the device's approved status.21 CFR 820.10
Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
Not flaggedFDA does not flag this code as life-supporting or life-sustaining.820.10(d) is not indicated by this flag.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
Complaint and record content21 CFR 820.35
Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions

These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.

Clearances and recalls on record

510(k), De Novo and BK numbers linked
0
PMA numbers linked
0
Recall product records
1
Adverse event reports
Search MAUDE for OAW

Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.

Search all 7,098 product codes, or read the guide to the Part 820 rules behind these flags.

Check your quality documents against Part 820

Arca puts your SOPs and design files in a library and compares them against the Part 820 requirements for your device in a grid, one row per document and one column per requirement, with each cell cited to its source.

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.