EU's Draft Annex 22 Limits Generative AI to Non-Critical GMP Work

The European Commission's draft Annex 22 on artificial intelligence says that generative AI tools such as ChatGPT "should not be used in critical GMP applications". A use is critical when it has "direct impact on patient safety, product quality or data integrity". Everywhere else the draft allows these models, provided a qualified, trained person is responsible for each output. The draft is not yet in force, but it rests on controls that EU inspectors already check. In half of the failed inspections we hold, they cite data integrity or computerised systems.
Even as a draft, Annex 22 is the best guide to what EU inspectors will look for, because inspectors wrote it. It would join EudraLex Volume 4, the EU's rules for good manufacturing practice (GMP) in making medicines. EMA's inspectors drafted it with PIC/S, a scheme through which inspectorates share GMP standards, and revised Annex 11 on computerised systems and Chapter 4 on documentation at the same time. The Commission consulted on all three from 7 July to 7 October 2025. On 18 November 2026 the Commission's EudraLex page still lists the 2011 Annex 11 and Chapter 4 and no Annex 22, so none of the three has been adopted.
Only fixed, repeatable models may run critical GMP steps
Annex 22 covers AI models, programs that learn a task from example data, "used in critical applications", and it admits only one kind to that work. The model must be static, so it does not change while in use, and deterministic, so the same input always gives the same output. Every other kind falls outside the annex and is kept out of critical uses.
| Kind of model | Covered by the draft? | What the draft says about critical uses |
|---|---|---|
| Static model with deterministic output, such as one that classifies products as accept or reject | Yes | Allowed, once it meets the annex's testing and operating requirements |
| Dynamic model that will "continuously and automatically learn and adapt performance during use" | No | "should not be used in critical GMP applications" |
| Model with probabilistic output, which "might not provide identical outputs" for identical inputs | No | "should not be used in critical GMP applications" |
| Generative AI and LLMs | No | "should not be used in critical GMP applications" |
| Generative AI and LLMs in non-critical uses | No | Allowed, with qualified staff responsible for each output |
A chat assistant built on a large language model (LLM) can give two different answers to the same question, so under this text no amount of testing would qualify one for a critical use. A company that wants AI in a critical step, such as visual inspection before release, should plan on a static classifier instead.
Generative AI is allowed in non-critical work if a qualified person answers for it
Outside critical uses, the draft puts the weight on people. It says "personnel with adequate qualification and training should always be responsible for ensuring that the outputs from such models are suitable for the intended use". The intended use is the task the model does and the decision its output feeds, which FDA calls the context of use. The draft lists no non-critical uses, so the line below is our reading, using the levels of risk we set out for AI in GMP work. A tool that answers questions, or drafts text that a person checks and signs, sits on the permitted side. A tool that suggests whether to release a batch does not, because the decision it feeds is critical. No generative tool may make a GMP decision on its own.
For drafted content, being responsible means a substantive review of the draft against its sources, recorded with the signature. FDA's first AI warning letter went to a drug maker whose staff skipped that review. A quality team should therefore record, for each planned generative use, why it is non-critical and who reviews its output.
A model in a critical step should perform at least as well as the process it replaces
For the static models it does cover, the draft sets an evidence bar that starts with the firm's own manual process. The model should perform "at least as high as the performance of the process it replaces", so the firm must measure that process first. Before testing, a process expert describes the task and its inputs, including "all common and rare variations". Test data should not be "used during development, training or validation of the model", and staff who saw it stay out of training. Testing records which inputs drove each result, and the model may mark a low-confidence result "undecided". Where a person makes the final decision, that person's "training and consistent performance" is monitored "like any other manual process". A firm should budget for this work as it would for validating any GMP system.
In half of the failed EU inspections we hold, inspectors cite data integrity or computer systems
The draft calls itself "additional guidance to Annex 11", so an AI tool in a plant is first a computerised system, and EU inspectors already find such systems wanting. When an inspection finds serious failures, the national authority publishes a statement of non-compliance in EudraGMDP, the EU database of GMP certificates. Our mirror holds 84 statements from 72 inspections. In 37 of the 72 inspections the statement cites data integrity or computerised systems, though none mentions AI. Nineteen statements say what failed. Nine describe a system that was not validated, and six an audit trail that was off or edit rights nobody controlled.
84 EU statements of serious GMP non-compliance, Jan 2019 to Oct 202637 of 72 inspections citing data integrity or computerised systems19 of 37 say what failed; each coded by hand45 of 45 quotes checked word for word against the statement
Open a row to read the inspectors' words; the highlight marks the words that put the inspection in that row. An inspection can sit in more than one row.
9 of the 37 inspections, newest first
InspectorsTwelve major deficiencies were identified. • Pharmaceutical Quality System deficiencies. • Inadequate documentation and data integrity controls. • Deficiencies in computerized systems validation and electronic data management. • Inadequate Contamination Control Strategy. • Deficiencies in aseptic process simulation (APS/media fill). • Deficiencies in environmental and microbiological monitoring. • Inadequate…
EudraGMDP (search by statement number)InspectorsThe IT software used for plasma management was not validated according to the complexity of the system.
EudraGMDP (search by statement number)InspectorsThis is shown by deficiencies identified in the management of deviations, CAPAs, changes, complaints, self-inspections, and the Product Quality Reviews (PQRs) that were assessed. 6) The approach to Computerized System Validation (CSV) and data integrity is inadequate. 7) Good Documentation Practices (GDocP) are not sufficiently adhered to, as demonstrated for example by the backlog of revisions for multiple…
EudraGMDP (search by statement number)
The coded inspections are in data (JSON).
Those failures would undo the draft's own safeguards. Annex 22 says an AI model's test data "should be protected by access control and audit trail functionality". When Malta's medicines authority inspected Zenzi Pharmaceutical Industries in Murbad, India, in March 2026, it found that the "Audit trail was disabled from chromatographic sequences in QC analysis". A site in that state could not show who had seen or changed a model's test data. Before adding AI, a quality team should confirm that the system underneath is validated, keeps its audit trail on and limits who can change data.
The scope may widen, but the draft is the standard to plan against
Industry has asked for room to use LLMs in critical work, and the drafting group has taken the request up. EMA's report of a workshop on 30 June and 1 July 2026 says consultation comments supported allowing LLMs "whether critical or non-critical". The group has discussed allowing them within a fully documented, risk-based control strategy. But EMA gives no date for a new text, and nothing in the report says which way the group will decide. A firm that plans against the current draft loses little if the scope later widens, so these are the questions to bring to a steering committee now.
- Which of our AI uses could directly affect patient safety, product quality or data integrity?
- Is any generative AI tool used in a critical step today, and if so, when does it come out?
- Who is the named, trained person responsible for each generative AI output?
- Does each review record the sources checked, what was corrected and what the signature means?
- Are the systems under our AI tools validated, with audit trails on and edit rights limited?
- Who will track Annex 22 until the final text is adopted?
Data and method
The regulatory text comes from the Commission's consultation drafts and EMA's workshop report, whose status we confirmed on 18 November 2026. The inspection counts come from the 84 EudraGMDP statements of GMP non-compliance in our mirror, issued from 28 January 2019 to 16 October 2026, grouped into 72 inspections. A keyword search flagged 37 that cite data integrity or computerised systems. We read all 37 and found no false matches, and found no missed ones among the other 35. We coded the 37 by hand and checked each quoted phrase against the statement. Our mirror may not hold every statement EudraGMDP has published, especially before 2024, and each statement summarises the findings without listing them all.
Downloads: statements, flagged and inspections, coded by failure.
Frequently asked questions
Can we use ChatGPT in our EU plants?
Under the draft, yes for non-critical work such as drafting or searching documents, with a qualified person responsible for each output. No for any use that directly affects patient safety, product quality or data integrity, such as releasing a batch.
Is Annex 22 in force?
No. The Commission consulted on the draft from 7 July to 7 October 2025, and on 18 November 2026 it had not adopted it.
What do we tell the auditor about our AI?
That every AI use is listed with its risk, that generative AI is limited to non-critical work with a named reviewer, and that the systems underneath are validated with audit trails on.