CR-114 fictional medical-device change traceability example Version 1.0 | 16 November 2026 | Arca Article: https://www.arca.inc/blog/design-change-control-under-the-qmsr All device records and assumptions are invented. No tests, clinical validation, engineering review or release approval were performed. This is an educational example, not a prescribed regulatory format or evidence of safety/compliance. Files matrix.csv: six stable requirement/release rows in each of two snapshots. records.csv: fictional versioned register. Summaries only; source documents, test protocols and results do not exist in this example. Read matrix.csv with a CSV reader. Use snapshot=initial or snapshot=resolved, not both as a single release matrix. Record references use ID@version and semicolon-separated lists. app_scope uses semicolon-separated app versions. All rows target proposed app 2.4. App 2.3 retains the 24-hour behavior. Field guide row_id: stable trace row, unchanged across snapshots. change_id: CR-114 is the shared fictional change request. fictional: yes in every row, including every register row. target_app: proposed app version being assessed. requirement_id: stable requirement or release-package identifier. before_requirement / after_requirement: prior and proposed wording. risk_id / risk_and_control: illustrative risk and proposed control, not a rating. verification_method: proposed check, not an executed protocol or result. validation_rationale: assessment needed; none establishes validation sufficiency. labeling_release_impact: version-specific IFU, support or release effect. source_refs: historical and proposed source-record references; history is allowed. verification_refs: only illustrative records scoped to the target app are accepted. decision_refs: open decisions are allowed as links and remain release blockers. disposition: example action or unresolved issue, not a reviewer signature. release_status: HOLD throughout. Link repair never means release authorization. Deliberate defect Initial TR-01 cites VR-RET@1: superseded and scoped to app 2.3 / 24 hours. Resolved TR-01 cites VR-RET@2: illustrative app 2.4 / 72-hour record summary. The other rows do not change. Only the reference defect is resolved. Validation scope, submission assessment and UDI decision remain open. Reproduce from the repository root (Python standard library only): python3 scripts/validate-design-change-traceability.py --demo python3 scripts/validate-design-change-traceability.py --snapshot initial python3 scripts/validate-design-change-traceability.py --snapshot resolved The initial check exits 1. The resolved check exits 0 for link consistency only. The demo exits 0 only if it finds exactly the intended initial defect and no resolved reference defects. It prints the continuing release hold separately. It checks IDs, versions, record kinds, statuses and app scopes. It cannot check test coverage, clinical validity, risk acceptability or regulatory compliance. For your own work: copy one snapshot, replace every fictional requirement, risk, reference and assumption, and attach actual controlled source records. Do not reuse the example's IDs or criteria as evidence about a real device. Primary regulatory sources checked 16 November 2026: 21 CFR 820.7 and 820.10: ISO 13485:2016 incorporation and design applicability. https://www.ecfr.gov/current/title-21/part-820 FDA final software-change guidance (October 2017), questions 3a/3b/4. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/deciding-when-submit-510k-software-change-existing-device 21 CFR 830.50: new device identifier for a new version or model. https://www.ecfr.gov/current/title-21/section-830.50