 "method": [
  {
   "value": "173",
   "label": "of the 445 published letters have a product quality section"
  },
  {
   "value": "115",
   "label": "of those sections have more than a few words left after FDA's redactions"
  },
  {
   "value": "96 of 96",
   "label": "quotes found word for word in the letter text, page headers aside"
  }
 ],
 "hint": "Open a topic to see the newest letters whose quality section names it. The highlight marks the keyword we counted; a letter can name several topics.",
 "rows": [
  {
   "id": "stability",
   "label": "Stability and shelf life (3.2.S.7, 3.2.P.8)",
   "count": 63,
   "records": [
    {
     "title": "CT-P43",
     "meta": [
      "Celltrion",
      "BLA 761338",
      "30 September 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "(1) The bacterial retention study is inadequate for the CT-P43 drug product, 130 mg/26 mL (5 mg/mL) single-dose vial for IV Repeat the bacterial retention study of the (2) The container closure integrity test (CCIT) dye ingress method used for stability testing of CT-P43 drug product, 130 mg/26 mL (5 mg/mL) single-dose vial for IV use is not validated to ensure reproducibility of results between different analysts.",
       "mark": [
        244,
        253
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761338Orig1Orig2s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "AK105",
     "meta": [
      "Akeso Biopharma Co.",
      "BLA 761258",
      "19 January 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "These should include, but not be limited to, safety testing results for the new cell bank(s), available cell bank stability test results, comparisons of cell growth data (e.g., growth kinetics, viability, VCD, characteristics of fermentation process, etc.), drug substance (DS) release data, and extended analytical characterization data (e.g., glycan analyses, primary, secondary and higher structure, results for…",
       "mark": [
        114,
        123
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761258_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Bortezomib",
     "meta": [
      "Shilpa Medicare",
      "NDA 212782",
      "1 August 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Perform a one-time leachable study on three drug product registration stability batches stored in an inverted position at the proposed long-term storage conditions; and submit the leachable data for multiple time points (e.g., 18 months, 24 months, 36 months etc.) through expiry.",
       "mark": [
        70,
        79
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212782Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "NNC0172-2021",
     "meta": [
      "Novo Nordisk",
      "BLA 761315",
      "24 April 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "…2023, you provided an assessment for the ‘ck on safety and effi The information and data provided are not sufficient to address the ri on safety and efficacy and the control strategy for is inadequate to ensure product quality, safety, and e sure product quality, safety, and efficacy as it relates 2) me address the following: (10) The drug substance (DS) release and stability specifications and their…",
       "mark": [
        370,
        379
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761315_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Pemetrexed",
     "meta": [
      "Shilpa Medicare",
      "NDA 215179",
      "14 April 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "1) Per ICH Q1A(R2), provide at least 12 months of long-term stability data on the NDA exhibit batches manufactured at the Cadila Healthcare Limited/Zydus Lifesciences Limited site (FEI#3007621329, DUNS#650348852). 2) Provide an acceptable leachables study performed on 12-month samples taken from the long-term stability study for the NDA exhibit batches manufactured at the Cadila Healthcare Limited/Zydus Lifesciences…",
       "mark": [
        60,
        69
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/215179_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Inadequate stability protocols were provided to support the requalification of Primary Reference Standards (PRS) and Working Reference Standards (WRS) that are used for testing against intermediate product, drug substance, and drug product samples.",
       "mark": [
        11,
        20
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kashiv BioSciences",
     "meta": [
      "BLA 761082",
      "2 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In response to FDA Item #4, you updated the stability protocols PTL-1981 “Stability Protocol for Theragrastim Primary Reference Standard Lot “Stability Protocol for Theragrastim Workin eference Standari r the working reference standards (WRS) to include a trending strategy and the acceptance criterion to control for EC50 values in the potency testing.",
       "mark": [
        44,
        53
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "PRV-031",
     "meta": [
      "Provention Bio",
      "BLA 761183",
      "2 July 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "(2) Results of your ongoing real-time stability studies demonstrate unacceptable charge variation measured in PRV-031 drug substance manufactured at AGC Biologics and the resulting drug product under recommended storage conditions.",
       "mark": [
        38,
        47
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761183_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In-use stability study performed on batches manufactured using the proposed commercial manufacturing process To date, these continue to be deficiencies.",
       "mark": [
        7,
        16
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Technegas Technetium Tc-99m carbon",
     "meta": [
      "Cyclomedica Australia Pty",
      "NDA 022335",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Characterization and control of the aerosol drug In the current review cycle, the NDA has not provided adequate characterization of the aerosol, including aerosol composition, batch formula, batch data, stability data, identity, strength, purity, delivered dose, generator yield, generator duty cycle and generator recertification period.",
       "mark": [
        203,
        212
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/022335Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Omeprazole and sodium bicarbonate",
     "meta": [
      "Azurity Pharmaceuticals",
      "NDA 213593",
      "28 January 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The following deficiencies are noted: (1) The strength of the active ingredient, sodium bicarbonate, in the drug product throughout the product shelf-life and during the in-use period is not adequately assured. a.",
       "mark": [
        144,
        154
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/213593_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Theragrastim",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761082",
      "22 December 2020"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The stability protocols PTL-1981 “Stability Protocol for Theragrastim Primary Reference Standard ™® «Stability Protocol for Theragrastim Working Reference Standard” are deficient because there are no acceptance criteria established to control for EC50 values.",
       "mark": [
        4,
        13
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "63 of 115 letters, newest 12 shown"
  },
  {
   "id": "specifications",
   "label": "Specifications and acceptance criteria (3.2.S.4, 3.2.P.5)",
   "count": 53,
   "records": [
    {
     "title": "CT-P43",
     "meta": [
      "Celltrion",
      "BLA 761338",
      "30 September 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Alternatively, measure all samples by spectrophotometry and provide an updated method description with acceptance criteria and submit additional method validation data accordingly.",
       "mark": [
        103,
        122
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761338Orig1Orig2s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Bortezomib",
     "meta": [
      "Shilpa Medicare",
      "NDA 212782",
      "1 August 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "However, to comply with MAPP 5019.1 (official as of January 28, 2022), we suggest you include a gross content test with upper and lower acceptance criteria in the drug product specification.",
       "mark": [
        136,
        155
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212782Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "NNC0172-2021",
     "meta": [
      "Novo Nordisk",
      "BLA 761315",
      "24 April 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "…an assessment for the ‘ck on safety and effi The information and data provided are not sufficient to address the ri on safety and efficacy and the control strategy for is inadequate to ensure product quality, safety, and e sure product quality, safety, and efficacy as it relates 2) me address the following: (10) The drug substance (DS) release and stability specifications and their justifications were provided…",
       "mark": [
        361,
        375
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761315_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kisunla (LY3002813)",
     "meta": [
      "Eli Lilly and Company",
      "BLA 761248",
      "18 January 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Include glycosylation profiling in the release specification for Kisunla drug substance using a validated testing method and establish acceptance criteria for main glycan forms, high mannose, and other afucosylated species with upper and lower limits, as applicable.",
       "mark": [
        47,
        60
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761248_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "CT-P17",
     "meta": [
      "Celitrion",
      "BLA 761219",
      "24 November 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "This may allow for the production of a batch that may meet oo] limits but exceeds the specification for release.",
       "mark": [
        86,
        99
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761219_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Xenoview (xenon-129 hyperpolarized)",
     "meta": [
      "Polarean",
      "NDA 214375",
      "5 October 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Establish specification and acceptance limits with tolerances (acceptable variation) with adequate justification per 21 CFR 314.50(d)(ii)(a).",
       "mark": [
        10,
        23
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/214375_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risperidone",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "24 September 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "As such, tighten the inherent viscosity specifications (both raw material and sterilized material). 4.",
       "mark": [
        40,
        54
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Insufficient data were provided to support the qualification of the WRS lot ata provided in the qualification repo! - -R) shows out of specification results or results that are not comparable, such as the following: Because of the above issues, we do not agree that the current in-house WRS has been qualifie appropriately.",
       "mark": [
        135,
        148
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kashiv BioSciences",
     "meta": [
      "BLA 761082",
      "2 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In response to FDA Item #4, you updated the stability protocols PTL-1981 “Stability Protocol for Theragrastim Primary Reference Standard Lot “Stability Protocol for Theragrastim Workin eference Standari r the working reference standards (WRS) to include a trending strategy and the acceptance criterion to control for EC50 values in the potency testing.",
       "mark": [
        282,
        302
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "PRV-031",
     "meta": [
      "Provention Bio",
      "BLA 761183",
      "2 July 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "To correct this deficiency, provide cell bank requalification protocols for the MCB and WCB to include, but not be limited to, the frequency of testing, a justification for this frequency, number of vials proposed to be tested at each testing timepoint, tests proposed/parameters to be evaluated, and appropriately justified acceptance criteria.",
       "mark": [
        325,
        344
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761183_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "BRM authentication should include genetic, chemical, or biological methods with appropriate acceptance criteria.",
       "mark": [
        92,
        111
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Technegas Technetium Tc-99m carbon",
     "meta": [
      "Cyclomedica Australia Pty",
      "NDA 022335",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "You have not established aerosol critical quality attributes and specifications to ensure the identity, strength, quality, purity, or potency of the drug product under 21 CFR 314.50(d) (ii)((a)).",
       "mark": [
        65,
        79
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/022335Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "53 of 115 letters, newest 12 shown"
  },
  {
   "id": "methods",
   "label": "Analytical methods and their validation (3.2.S.4.2, 3.2.P.5.2)",
   "count": 42,
   "records": [
    {
     "title": "CT-P43",
     "meta": [
      "Celltrion",
      "BLA 761338",
      "30 September 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "According to FDA guidance for industry “Analytical Procedures and Methods Validation for Drugs and Biologics (2015)”, for non-compendial method, validation data are needed to support the reproducibility of the method.",
       "mark": [
        40,
        61
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761338Orig1Orig2s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "AK105",
     "meta": [
      "Akeso Biopharma Co.",
      "BLA 761258",
      "19 January 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Provide updated method procedures (if applicable) and method validation/revalidation results to support the suitability of these methods for routine process and product control.",
       "mark": [
        54,
        71
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761258_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Bortezomib",
     "meta": [
      "Shilpa Medicare",
      "NDA 212782",
      "1 August 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Also, provide a description of the analytical procedure, an appropriate method validation study, and test results for the NDA exhibit batches. 2.",
       "mark": [
        35,
        55
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212782Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kisunla (LY3002813)",
     "meta": [
      "Eli Lilly and Company",
      "BLA 761248",
      "18 January 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Provide the results of the method validation for glycosylation profiling and the data and analysis used to set acceptance criteria.",
       "mark": [
        27,
        44
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761248_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "BAT1706",
     "meta": [
      "Bio-Thera Solutions",
      "BLA 761198",
      "19 November 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Alternatively, revise the analytical method description to specify the source of the labeling reagent used as part of the analytical method validation.",
       "mark": [
        26,
        43
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761198_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risperidone",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "24 September 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The observed high variabilities could come from inconsistent drug product quality, dissolution method, analytical method/assay, or other sources.",
       "mark": [
        103,
        120
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Inadequate information was provided to support recent changes made to the cell- In response to an information request (received on 01/08/2021, Seq. , you provided additional information stating that the potency assays have been revised according to change control procedures (CC-20-036 and CC- 20- 045).",
       "mark": [
        203,
        217
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kashiv BioSciences",
     "meta": [
      "BLA 761082",
      "2 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "You should evaluate whether there is a EC50 value drift based on the absolute values generated in the potency assay. ii.",
       "mark": [
        102,
        115
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "However, at this time, this continues to be a deficiency. 11.The method suitability for bioburden release testing for DS did not meet acceptance criteria for ™® Repeat the bioburden test method suitability for burden testing of the DS. 12.",
       "mark": [
        182,
        193
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Technegas Technetium Tc-99m carbon",
     "meta": [
      "Cyclomedica Australia Pty",
      "NDA 022335",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Propose and describe analytical methods suitable for their intended purpose, with appropriate validation.",
       "mark": [
        21,
        39
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/022335Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Omeprazole and sodium bicarbonate",
     "meta": [
      "Azurity Pharmaceuticals",
      "NDA 213593",
      "28 January 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The suitability of proposed assay method for the active ingredient sodium bicarbonate wy) has not been fully demonstrated.",
       "mark": [
        28,
        40
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/213593_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Acetaminophen",
     "meta": [
      "InnoPharma Licensing",
      "NDA 206968",
      "22 December 2020"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Information needed to resolve deficiency Reanalyze the 9-month and subsequent stability time points, using the fully validated methods that you are developing.",
       "mark": [
        117,
        134
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/206968_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "42 of 115 letters, newest 12 shown"
  },
  {
   "id": "substance",
   "label": "Drug substance, starting materials and reference standards (3.2.S)",
   "count": 39,
   "records": [
    {
     "title": "AK105",
     "meta": [
      "Akeso Biopharma Co.",
      "BLA 761258",
      "19 January 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "To resolve these deficiencies, provide data and information to support the qualification of an adequate and well-controlled cell bank(s) to ensure the manufacture of penpulimab-kcqx that is of continued product safety, purity, and potency.",
       "mark": [
        124,
        133
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761258_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Lebrikizumab",
     "meta": [
      "Eli Lilly and Company",
      "BLA 761306",
      "28 September 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Further, the adequacy of the proposed lebrikizumab drug substance (DS) manufacturing process and overall control BLA strategy cannot be determined at this time to support the licensure of lebrikizumab.",
       "mark": [
        51,
        65
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761306_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "ARS Pharmaceuticals",
     "meta": [
      "NDA 214697",
      "19 September 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Deficiency FDA expects manufacturers and applicants to ascertain the presence of Nitrosamine Drug Substance-Related Impurities (NDSRIs) in their drug products.",
       "mark": [
        93,
        107
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/214697_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "NNC0172-2021",
     "meta": [
      "Novo Nordisk",
      "BLA 761315",
      "24 April 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "…Agency’s IR dated uary 16, 2023, you provided an assessment for the ‘ck on safety and effi The information and data provided are not sufficient to address the ri on safety and efficacy and the control strategy for is inadequate to ensure product quality, safety, and e sure product quality, safety, and efficacy as it relates 2) me address the following: (10) The drug substance (DS) release and stability…",
       "mark": [
        365,
        379
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761315_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kisunla (LY3002813)",
     "meta": [
      "Eli Lilly and Company",
      "BLA 761248",
      "18 January 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Include glycosylation profiling in the release specification for Kisunla drug substance using a validated testing method and establish acceptance criteria for main glycan forms, high mannose, and other afucosylated species with upper and lower limits, as applicable.",
       "mark": [
        73,
        87
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761248_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risvan (risperidone ISM)",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "15 July 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Sterile Drug Substance Risperidone The referenced DMF for sterile drug substance risperidone has been reviewed and determined to be inadequate.",
       "mark": [
        8,
        22
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Coherus BioSciences",
     "meta": [
      "BLA 761240",
      "29 April 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Submit change control report(s) demonstrating implementation of the virus testing for UPB for all products manufactured on the same equipment as toripalimab drug substance.",
       "mark": [
        157,
        171
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761240_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risperidone",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "24 September 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "As such, tighten the inherent viscosity specifications (both raw material and sterilized material). 4.",
       "mark": [
        61,
        73
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The bacterial retention study for the sterilizing-grade filter was performed using the drug substance, which is not adequate.",
       "mark": [
        87,
        101
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Kashiv BioSciences",
     "meta": [
      "BLA 761082",
      "2 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In response to FDA Item #4, you updated the stability protocols PTL-1981 “Stability Protocol for Theragrastim Primary Reference Standard Lot “Stability Protocol for Theragrastim Workin eference Standari r the working reference standards (WRS) to include a trending strategy and the acceptance criterion to control for EC50 values in the potency testing.",
       "mark": [
        118,
        136
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "PRV-031",
     "meta": [
      "Provention Bio",
      "BLA 761183",
      "2 July 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "(2) Results of your ongoing real-time stability studies demonstrate unacceptable charge variation measured in PRV-031 drug substance manufactured at AGC Biologics and the resulting drug product under recommended storage conditions.",
       "mark": [
        118,
        132
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761183_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Botanical raw material (BRM) authentication is solely based on morphology.",
       "mark": [
        10,
        22
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "39 of 115 letters, newest 12 shown"
  },
  {
   "id": "container",
   "label": "Container closure, extractables and leachables (3.2.P.7)",
   "count": 36,
   "records": [
    {
     "title": "CT-P43",
     "meta": [
      "Celltrion",
      "BLA 761338",
      "30 September 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "(1) The bacterial retention study is inadequate for the CT-P43 drug product, 130 mg/26 mL (5 mg/mL) single-dose vial for IV Repeat the bacterial retention study of the (2) The container closure integrity test (CCIT) dye ingress method used for stability testing of CT-P43 drug product, 130 mg/26 mL (5 mg/mL) single-dose vial for IV use is not validated to ensure reproducibility of results between different analysts.",
       "mark": [
        176,
        193
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761338Orig1Orig2s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Bortezomib",
     "meta": [
      "Shilpa Medicare",
      "NDA 212782",
      "1 August 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Perform a one-time leachable study on three drug product registration stability batches stored in an inverted position at the proposed long-term storage conditions; and submit the leachable data for multiple time points (e.g., 18 months, 24 months, 36 months etc.) through expiry.",
       "mark": [
        19,
        28
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212782Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Pemetrexed",
     "meta": [
      "Shilpa Medicare",
      "NDA 215179",
      "14 April 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "1) Per ICH Q1A(R2), provide at least 12 months of long-term stability data on the NDA exhibit batches manufactured at the Cadila Healthcare Limited/Zydus Lifesciences Limited site (FEI#3007621329, DUNS#650348852). 2) Provide an acceptable leachables study performed on 12-month samples taken from the long-term stability study for the NDA exhibit batches manufactured at the Cadila Healthcare Limited/Zydus Lifesciences…",
       "mark": [
        239,
        249
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/215179_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risperidone",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "24 September 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "We acknowledge the provided container closure integrity validation reports for the drug product and the diluent DMSO (UDMI-IVP-21-013/00 and UDMI-IVP-21- 014/00) by microbial immersion method in 1.11.1 (Seq-0023).",
       "mark": [
        28,
        45
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Summarized results (media fill date, container closure, filled volume, duration, number of units filled/incubated/rejected, positive) from the three initial media fill validation runs and the latest requalification run that was performed to validate the syringe line filling process relevant to the drug product. b.",
       "mark": [
        37,
        54
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "PRV-031",
     "meta": [
      "Provention Bio",
      "BLA 761183",
      "2 July 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In order to accomplish this, address the following: (by (4) (5) Insufficient information was provided regarding the levels and types of leachates in PRV-031 derived from its container closure and the risk to patients from any leachates that are potentially present in the drug product during its shelf life.",
       "mark": [
        174,
        191
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761183_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Report RP-V-P-0163 for container closure integrity test (CCIT) validation does not meet the acceptance criteria to detect 20 micron leaks.",
       "mark": [
        23,
        40
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Carmustine",
     "meta": [
      "Accord Healthcare",
      "NDA 215000",
      "30 April 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Conduct a leachable study using the conditions that represent the worst case scenario, i.e., aged samples under the long term and accelerated conditions. .",
       "mark": [
        10,
        19
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/215000_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Omeprazole and sodium bicarbonate",
     "meta": [
      "Azurity Pharmaceuticals",
      "NDA 213593",
      "28 January 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The drug product batches should be packaged in the to-be-marketed container closure systems and manufactured at no less than 1/10th of the intended commercial scale.",
       "mark": [
        66,
        83
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/213593_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Theragrastim",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761082",
      "22 December 2020"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Also, we noted you schedule to test container closure integrity (CCI) only at the 12-month time-point but not at the 24-month time-point.",
       "mark": [
        36,
        53
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Acetaminophen",
     "meta": [
      "InnoPharma Licensing",
      "NDA 206968",
      "22 December 2020"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Your PDE-based approach to selecting targeted leachables is concerning because not all leachables above the 5 mcg/day threshold may be observed.",
       "mark": [
        46,
        56
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/206968_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Cantharidin",
     "meta": [
      "Verrica Pharmaceuticals",
      "NDA 212905",
      "13 July 2020"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "(2) The extraction solutions, ®® used in the extractable/leachable study are considered inadequate because: b.",
       "mark": [
        45,
        56
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212905_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "36 of 115 letters, newest 12 shown"
  },
  {
   "id": "process",
   "label": "Process validation and in-process control (3.2.S.2, 3.2.P.3)",
   "count": 28,
   "records": [
    {
     "title": "CSL312 (garadacimab)",
     "meta": [
      "CSL Behring",
      "BLA 761367",
      "7 October 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In the BLA resubmission, provide complete process validation data for the CSL312 SFP manufacturing process with and update Module 3.2.P of the BLA to reflect the new process accordingly.",
       "mark": [
        42,
        60
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761367Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "CT-P43",
     "meta": [
      "Celltrion",
      "BLA 761338",
      "30 September 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In addition, this specification is not supported by the updated full term (36 months) stability data from the primary stability (non-PPQ) batches provided in the same amendment in SN 0027, which consistently showed results are below{NTU at all timepoints throughout the product shelf life.",
       "mark": [
        133,
        136
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761338Orig1Orig2s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "AK105",
     "meta": [
      "Akeso Biopharma Co.",
      "BLA 761258",
      "19 January 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Reference is made to the information and data provided in the original submission and in response to the Agency's IR dated September 9, 2021, concerning the penpulimab-kcqx drug product (DP) manufacturing process control strategy.",
       "mark": [
        205,
        220
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761258_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Lebrikizumab",
     "meta": [
      "Eli Lilly and Company",
      "BLA 761306",
      "28 September 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "If any impacted data are removed from the application and/or changes are made to the control strategy to address the facility deficiencies, provide additional information and data (e.g., testing results from repeated studies) that are reliable and accurate to support that consistent process performance and product quality is achieved.",
       "mark": [
        85,
        101
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761306_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "NNC0172-2021",
     "meta": [
      "Novo Nordisk",
      "BLA 761315",
      "24 April 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "In addition, in the response received on February 28, 2023 to the Agency’s IR dated uary 16, 2023, you provided an assessment for the ‘ck on safety and effi The information and data provided are not sufficient to address the ri on safety and efficacy and the control strategy for is inadequate to ensure product quality, safety, and e sure product quality, safety, and efficacy as it relates 2) me address the…",
       "mark": [
        259,
        275
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761315_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Coherus BioSciences",
     "meta": [
      "BLA 761240",
      "29 April 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "To address the deficiency, provide the following information on control strategy and measures implemented to assure that all toripalimab batches are produced per current industry standards and aligned with ICH Q5A guidelines: a.",
       "mark": [
        64,
        80
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761240_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Limited process validation data were provided for the downstream drug roduct filling operations (Section 3.2.P.3.5, Report CMO-0174). additional process validation runs by analyzing multiple individual syringes at the beginning, middle, and end of fill to support the homogeneity of the filling operation to ensure the label claim is met for all syringes filled. b.",
       "mark": [
        8,
        26
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "PRV-031",
     "meta": [
      "Provention Bio",
      "BLA 761183",
      "2 July 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "This should include, but not be limited to, batch release data, stability data, in-process testing, process characterization studies, and the comparability assessment between the clinical material manufactured at Eli Lilly and the proposed commercial material manufactured at AGC Biologics.",
       "mark": [
        80,
        90
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761183_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The overall microbial control strategy does not mitigate the risk of potential adventitious agents that may be introduced during the manufacturing process.",
       "mark": [
        22,
        38
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Technegas Technetium Tc-99m carbon",
     "meta": [
      "Cyclomedica Australia Pty",
      "NDA 022335",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Validation of the aerosol drug production and documentation To address this issue, as outlined in Approvability Issue #1, provide aerosol batch data from validated analytical methods for at least three registration batches to support your commercial aerosol drug production and in-process controls at the minimum and maximum crucible load of sodium pertechnetate radioactivity.",
       "mark": [
        278,
        288
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/022335Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Omeprazole and sodium bicarbonate",
     "meta": [
      "Azurity Pharmaceuticals",
      "NDA 213593",
      "28 January 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Based on our review of the chemistry, manufacturing, and controls information provided in the original submission and reviewed amendments, we find that the proposed control strategy is insufficient to assure the identity, strength, purity, quality, and bioavailability of the drug product as required by 21 CFR 314.50.",
       "mark": [
        165,
        181
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/213593_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Otulinum toxin Type A",
     "meta": [
      "Evolus",
      "BLA 761085",
      "15 May 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Examples of these changes include i) process validation data from three new drug product (DP) lots manufactured with an updated commercial DP manufacturing process in an amendment received on December 15, 2017, and ii) changes to the DP post approval stability protocol to eliminate testing time points in an amendment received on December 1, 2017.",
       "mark": [
        37,
        55
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761085_2019_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "28 of 115 letters, newest 12 shown"
  },
  {
   "id": "sterility",
   "label": "Sterility, endotoxin and microbial control (3.2.P.3, 3.2.P.5)",
   "count": 24,
   "records": [
    {
     "title": "CT-P43",
     "meta": [
      "Celltrion",
      "BLA 761338",
      "30 September 2024"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The post-use integrity test result should be accurate to support sterility assurance of the product.",
       "mark": [
        65,
        74
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761338Orig1Orig2s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risvan (risperidone ISM)",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "15 July 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Sterile Drug Substance Risperidone The referenced DMF for sterile drug substance risperidone has been reviewed and determined to be inadequate.",
       "mark": [
        0,
        7
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Coherus BioSciences",
     "meta": [
      "BLA 761240",
      "29 April 2022"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "ICH guideline Q5A Quality of Biotechnological Products: Viral Safety Evaluation of Biotechnology Products Derived from Cell Lines of Human or Animal Origin recommends that “Appropriate testing for viruses should be performed at the unprocessed bulk level [...]” and “the safety of these products [biotechnology products derived from cell lines] with regard to viral contamination can be reasonably assured only by the…",
       "mark": [
        366,
        379
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761240_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "BAT1706",
     "meta": [
      "Bio-Thera Solutions",
      "BLA 761198",
      "19 November 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The low endotoxin recovery (LER) study was conducted for aa which is not representative of the product storage during DP manufacturing i Conduct a new LER study to account for the DP manufacturing time and provide the summary data and report, including endotoxin level recovered and percentage of recovery for all the test points.",
       "mark": [
        8,
        17
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761198_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Risperidone",
     "meta": [
      "Laboratorios Farmaceuticos Rovi",
      "NDA 214835",
      "24 September 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "As such, tighten the inherent viscosity specifications (both raw material and sterilized material). 4.",
       "mark": [
        78,
        88
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/Pages%20from%20214835Orig1s000_ORIGINAL_APPROVAL_PACKAGE.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TPI-120",
     "meta": [
      "Kashiv BioSciences",
      "BLA 761084",
      "11 August 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The bacterial retention study for the sterilizing-grade filter was performed using the drug substance, which is not adequate.",
       "mark": [
        38,
        49
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761084_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The overall microbial control strategy does not mitigate the risk of potential adventitious agents that may be introduced during the manufacturing process.",
       "mark": [
        12,
        21
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Tralokinumab",
     "meta": [
      "LEO Pharma A/S",
      "BLA 761180",
      "23 April 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Failure of the needle safety device to perform adequately may result in serious risks (accidental contaminated needle sticks).",
       "mark": [
        98,
        110
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761180_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Pemetrexed",
     "meta": [
      "Actavis LLC, an indirect, wholly-owned subsidiary of Teva Pharmaceuticals U.S.A.",
      "NDA 208419",
      "26 June 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The method suitability report NV/TR00385 version 1 for the bacterial endotoxins test performed by the kinetic-turbidimetric method at the Actavis Italy S. facility is acknowledged.",
       "mark": [
        69,
        79
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/208419_2021_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Otulinum toxin Type A",
     "meta": [
      "Evolus",
      "BLA 761085",
      "15 May 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "You provided no in-process bioburden and endotoxin data to demonstrate adequate addition, provide the qualification data for the bioburden and endotoxin test methods Furthermore, establish and provide in-process limits for these bioburden and endotoxin samples. 6.",
       "mark": [
        27,
        36
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761085_2019_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Adello Biologics",
     "meta": [
      "BLA 761082",
      "10 May 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "The end of the fermentation production does not include a bacterial purity test to monitor for possible contamination.",
       "mark": [
        104,
        117
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Trazimera (PF-05280014)",
     "meta": [
      "Pfizer",
      "BLA 761081",
      "20 April 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Provide summary microbial data from hold time studies conducted in the holding vessels used for PF-05280014 in the BLA resubmission. 11.",
       "mark": [
        16,
        25
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761081_2019_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "24 of 115 letters, newest 12 shown"
  },
  {
   "id": "impurities",
   "label": "Impurities (3.2.S.3, 3.2.P.5.5)",
   "count": 19,
   "records": [
    {
     "title": "ARS Pharmaceuticals",
     "meta": [
      "NDA 214697",
      "19 September 2023"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Deficiency FDA expects manufacturers and applicants to ascertain the presence of Nitrosamine Drug Substance-Related Impurities (NDSRIs) in their drug products.",
       "mark": [
        81,
        92
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/214697_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "MediWound",
     "meta": [
      "BLA 761192",
      "25 June 2021"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Elemental analysis by ICP-MS on the DP and the gel vehicle (GV) in their final container closure system e.",
       "mark": [
        0,
        9
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761192_2023_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Bortezomib",
     "meta": [
      "Shilpa Medicare",
      "NDA 212782",
      "10 March 2020"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "(3) Revise the release and stability specification for Degradation Products to all known and unknown impurities, and degradants observed at or above method limit of quantitation, and to report total impurities as the sum of al observed known and unknown impurities, or degradants.",
       "mark": [
        55,
        75
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212782Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Naloxone hydrochloride",
     "meta": [
      "Adamis Pharmaceuticals",
      "NDA 212854",
      "22 November 2019"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "To address this deficiency: Unequivocally establish the structures of the photo-degradants at RRT by comparison with reference standards if available, or spectroscopic techniques such as Mass spectra, UV, IR and NMR.",
       "mark": [
        80,
        90
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/212854_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "TX01",
     "meta": [
      "Tanvex BioPharma USA",
      "BLA 761126",
      "24 September 2019"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "…report for analytical characterization of TX01 and Neupogen on Charge Heterogeneity by CEX-HPLC” you mentioned that although the same assay was used for the 2016 and 2018 analyses, there were sensitivity differences in detection of low levels of acidic and basic species that resulted in slight differences in the integrated and reported levels of purity and impurities between the two studies.",
       "mark": [
        360,
        370
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761126_2025_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Anjeso (meloxicam)",
     "meta": [
      "Recro Pharma",
      "NDA 210583",
      "23 May 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "A lack of correlation may imply that the extractable study was not conducted vigorously enough to extract all possible impurities.",
       "mark": [
        119,
        129
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/210583_2020_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Insulin glargine",
     "meta": [
      "Mylan",
      "NDA 210605",
      "17 May 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Equations used for impurity calculations to the HPLC and SEC impurity methods. ii.",
       "mark": [
        19,
        27
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/210605_2020_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Adello Biologics",
     "meta": [
      "BLA 761082",
      "10 May 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Commercial DS Theragrastim lots 20-17001, 20-17002, and 20-17003 and DP Theragrastim lots 170086, 170087, and 170088 have total charge impurity levels outside the US-licensed Neupogen quality range. ' Your proposed proprietary name, Releuko, and proposed proper name, filgrastim-ayow, are conditionally accepted until such time that the application is approved.",
       "mark": [
        135,
        143
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/761082_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Daptomycin",
     "meta": [
      "Hospira",
      "NDA 210282",
      "19 March 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Provide a product risk assessment focused on assessing the levels of elemental impurities in the drug product in relation to the safety recommendations in the ICH Q3D Elemental Impurities guidance available at https://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ UCM371025.pdf For additional information, see: https://www.fda.gov/Drugs/DevelopmentA…",
       "mark": [
        69,
        78
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/210282_2022_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "Bortezomib",
     "meta": [
      "Hospira",
      "NDA 209191",
      "22 February 2018"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "Establish a validated test method for elemental impurities as part of the drug product specification consistent with ICH Q3D and USP <232/233>.",
       "mark": [
        38,
        47
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/209191_2018_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "AFT Pharmaceuticals",
     "meta": [
      "NDA 209471",
      "22 December 2017"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "To address this deficiency, tighten your total impurity specifications for release and stability based on the data you have provided in the NDA. 7.",
       "mark": [
        47,
        55
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/209471_2024_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    },
    {
     "title": "SoluPrep",
     "meta": [
      "3M Health Care (Infection Prevention Division)",
      "NDA 208288",
      "6 May 2016"
     ],
     "quotes": [
      {
       "label": "FDA",
       "text": "These degradants continue to rise and accumulate in the drug product throughout the shelf-life.",
       "mark": [
        6,
        16
       ],
       "tone": "source"
      }
     ],
     "url": "https://download.open.fda.gov/crl/208288_2018_Orig1s000OtherActionLtrs.pdf",
     "urlLabel": "Read the letter"
    }
   ],
   "note": "19 of 115 letters, newest 12 shown"
  }
 ],
 "download": "These cards are in the {json}, and every letter with its topics is in the CSV below."
}